Suppr超能文献

兔子正常的c波振幅。

The normal c-wave amplitude in rabbits.

作者信息

Naoi N, Kim S Y, Honda Y

出版信息

Doc Ophthalmol. 1986 Jul 15;63(2):121-30. doi: 10.1007/BF00157121.

Abstract

We examined some of the problems arising when c-waves are employed in pharmacological experiments with pigmented rabbits. The cyclic variations of the c-wave are smaller in rabbit than in other species. Under our experimental conditions the c-wave amplitudes in some rabbits reached an equilibrium under intermittent stimuli, while in others they increased with time and did not reach a constant level within 3 h. The c-wave amplitude varied with the standing potential during dark adaptation. However interindividual variations made it difficult to standardize the c-waves by this change. Since the c-wave amplitudes of the right and left eyes were similar, the contralateral eye should be used as a control when drugs are administered topically. Interindividual variations of the c-wave amplitude were smaller under dim light. This method is useful in chronic pharmacological experiments when drugs are administered systemically.

摘要

我们研究了在有色家兔的药理学实验中使用c波时出现的一些问题。家兔c波的周期性变化比其他物种小。在我们的实验条件下,一些家兔的c波振幅在间歇性刺激下达到平衡,而在另一些家兔中,它们随时间增加,在3小时内未达到恒定水平。在暗适应过程中,c波振幅随静息电位而变化。然而,个体差异使得难以通过这种变化来标准化c波。由于左右眼的c波振幅相似,局部给药时应使用对侧眼作为对照。在暗光下,c波振幅的个体差异较小。当全身给药时,这种方法在慢性药理学实验中很有用。