Abstract

OBJECTIVE

To evaluate two different dual-energy computed tomography (DECT) post-processing protocols for the detection of MSU deposits in foot tendons of cadavers with verification by polarizing light microscopy as the gold standard.

MATERIAL AND METHODS

A total of 40 embalmed cadavers (15 male; 25 female; median age, 82 years; mean, 80 years; range, 52-99; SD ± 10.9) underwent DECT to assess MSU deposits in foot tendons. Two postprocessing DECT protocols with different Hounsfield unit (HU) thresholds, 150/500 (=established) versus 120/500 (=modified). HU were applied to dual source acquisition with 80 kV for tube A and 140 kV for tube B. Six fresh cadavers (4 male; 2 female; median age, 78; mean, 78.5; range 61-95) were examined by DECT. Tendon dissection of 2/6 fresh cadavers with positive DECT 120 and negative DECT 150 studies were used to verify MSU deposits by polarizing light microscopy.

RESULTS

The tibialis anterior tendon was found positive in 57.5%/100% (DECT 150/120), the peroneus tendon in 35%/100%, the achilles tendon in 25%/90%, the flexor halluces longus tendon in 10%/100%, and the tibialis posterior tendon in 12.5%/97.5%. DECT 120 resulted in increased tendon MSU deposit detection, when DECT 150 was negative, with an overall agreement between DECT 150 and DECT 120 of 80% ( = 0.013). Polarizing light microscope confirmed MSU deposits detected only by DECT 120 in the tibialis anterior, the achilles, the flexor halluces longus, and the peroneal tendons.

CONCLUSION

The DECT 120 protocol showed a higher sensitivity when compared to DECT 150.

摘要

目的

以偏振光显微镜检查作为金标准,评估两种不同的双能计算机断层扫描(DECT)后处理方案在检测尸体足部肌腱中焦磷酸钙双水合物(MSU)沉积方面的效果。

材料与方法

共40具防腐处理的尸体(15例男性;25例女性;年龄中位数82岁;平均80岁;范围52 - 99岁;标准差±10.9)接受DECT检查以评估足部肌腱中的MSU沉积。两种具有不同亨氏单位(HU)阈值的DECT后处理方案,150/500(=既定方案)与120/500(=改良方案)。HU应用于管A为80 kV、管B为140 kV的双源采集。对6具新鲜尸体(4例男性;2例女性;年龄中位数78岁;平均78.5岁;范围61 - 95岁)进行DECT检查。对2/6例DECT 120阳性而DECT 150阴性的新鲜尸体进行肌腱解剖,通过偏振光显微镜检查验证MSU沉积。

结果

胫前肌腱在DECT 150/120方案下的阳性率分别为57.5%/100%,腓骨肌腱为35%/100%,跟腱为25%/90%,拇长屈肌腱为10%/100%,胫后肌腱为12.5%/97.5%。当DECT 150为阴性时,DECT 120能检测到更多的肌腱MSU沉积,DECT 150与DECT 120的总体一致性为80%(P = 0.013)。偏振光显微镜证实仅在DECT 120检测到的胫前肌、跟腱、拇长屈肌和腓骨肌腱中有MSU沉积。

结论

与DECT 150相比,DECT 120方案显示出更高的敏感性。