Roszkowska Anna M, Tumminello Giuseppe, Licitra Carmelo, Severo Alice A, Inferrera Leandro, Camellin Umberto, Schiano-Lomoriello Domenico, Aragona Pasquale
Ophthalmology Clinic, Department of Biomedical Sciences, University of Messina, 98100 Messina, Italy.
Department of Ophthalmology, Andrzej Frycz Modrzewski Krakow University, 30-705 Krakow, Poland.
J Clin Med. 2023 Jun 27;12(13):4311. doi: 10.3390/jcm12134311.
To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser.
The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined.
The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to -0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from -0.03 ± 0.06 to -0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from -4.90 ± 2.12 D to -0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines.
PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.
研究使用紫外全固态激光器进行准分子激光原位角膜磨镶术(PRK)的12个月临床和屈光结果。
该研究纳入了因屈光手术而接受PRK治疗的近视和/或复合性近视散光的健康患者,使用波长210nm、重复频率2kHz的紫外全固态激光器(LaserSoft,Katana Technologies GmbH,德国克莱因马赫诺)。所有受试者在基线时以及治疗后1、3、6和12个月接受检查,检查项目包括裂隙灯检查、验光、视力评估(对数最小分辨角视力表)、眼压测量、检眼镜检查以及使用三维 Scheimpflug 相机进行角膜地形图检查。所考虑的结果指标包括未矫正(UDVA)和矫正(CDVA)远视力、屈光、中央角膜厚度和透明度。确定了疗效、安全性、可预测性和稳定性。
该研究纳入了19名患者的34只眼。12个月时,平均未矫正远视力从1.20±0.43对数最小分辨角视力提高到-0.05±0.10对数最小分辨角视力,平均矫正远视力分别从-0.03±0.06对数最小分辨角视力变为-0.06±0.09对数最小分辨角视力。平均球镜等效度(SE)从-4.90±2.12D变为-0.01±0.40D,12个月时91%的眼睛在预期矫正的±0.50D范围内,97%的眼睛在±1.00D范围内。没有眼睛视力下降,64%的眼睛视力提高了一行或多行。
随访12个月后,使用波长210nm、重复频率2kHz的全固态激光LaserSoft系统进行的PRK显示出良好的视力、屈光和临床结果。新兴的无气体固态技术可能被认为是角膜屈光手术中气体操作激光器的有效替代方案。