Suppr超能文献

应用灰阶超声及剪切波弹性成像技术评估原发性干燥综合征患者泪腺受累情况。

Assessment of lacrimal gland involvement in primary Sjögren's syndrome using gray-scale ultrasonography and shear wave elastography.

机构信息

Department of Radiology, Faculty of Medicine, Selçuk University, Konya, 42131, Turkey.

Division of Rheumatology, Department of Internal Medicine, Faculty of Medicine, Selçuk University, Konya, Turkey.

出版信息

Eur Radiol. 2023 Dec;33(12):9368-9377. doi: 10.1007/s00330-023-09943-z. Epub 2023 Jul 20.

Abstract

OBJECTIVES

The aim of this study was to assess lacrimal gland involvement in primary Sjögren's syndrome (pSS) using lacrimal gland gray-scale ultrasound (LGUS) and two-dimensional shear wave elastography (2D-SWE).

METHODS

Eighty-five pSS patients with a mean age of 51.16 ± 10.61 years and 84 sex- and age-matched healthy subjects with a mean age of 50.94 ± 11.05 years were included in the study. Lacrimal gland parenchymal findings and 2D-SWE values were compared between the two groups and the correlations of LGUS parameters with clinical findings, dry eye tests, and minor salivary gland biopsy (MSGB) were further investigated.

RESULTS

LGUS parenchymal grade was 0 in 14 (16.5%), 1 in 45 (52.9%), 2 in 23 (27.1%), and 3 in 3 patients (3.5%) in the pSS group, while in the control group, parenchymal grades were 0 (57.1%) and 1 (42.9%). The mean 2D-SWE value of pSS patients was significantly higher than the control group (p < 0.05) and increased parallel with lacrimal parenchymal grade. The elasticity modulus had a high diagnostic performance in detecting lacrimal gland involvement in pSS patients (AUC 0.901, sensitivity 70.6%, specificity 97.6%), while the diagnostic performance of LGUS was much lower (AUC 0.769, sensitivity 83.5%, specificity 57.1%). LGUS and 2D-SWE values were found to be correlated with dry eye tests and MSGB results (p < 0.05).

CONCLUSIONS

LGUS and 2D-SWE are both useful for assessing the lacrimal gland involvement in pSS patients; however, 2D-SWE has a better diagnostic performance than LGUS and found to be correlated with dry eye tests.

CLINICAL RELEVANCE STATEMENT

Lacrimal gland US and two-dimensional shear wave elastography (2D-SWE) are imaging modalities that can be used to demonstrate parenchymal involvement of the lacrimal gland in primary Sjögren's syndrome (pSS).

KEY POINTS

• Gray-scale US and two-dimensional shear wave elastography (2D-SWE) have been widely used in the recent decade to assess gland involvement in patients with primary Sjögren's syndrome (pSS). • The elasticity modulus had a high diagnostic performance in detecting lacrimal gland involvement in primary Sjögren's syndrome (pSS) patients. • Lacrimal gland US and two-dimensional shear wave elastography (2D-SWE) are both useful for assessing the lacrimal gland in primary Sjögren's syndrome (pSS) patients; however, two-dimensional shear wave elastography (2D-SWE) has a better diagnostic performance than lacrimal gland ultrasound (LGUS).

摘要

目的

本研究旨在使用泪腺灰阶超声(LGUS)和二维剪切波弹性成像(2D-SWE)评估原发性干燥综合征(pSS)患者的泪腺受累情况。

方法

纳入 85 例平均年龄为 51.16±10.61 岁的 pSS 患者和 84 名年龄和性别匹配的健康对照者,平均年龄为 50.94±11.05 岁。比较两组患者的泪腺实质表现和 2D-SWE 值,并进一步探讨 LGUS 参数与临床发现、干眼检查和小唾液腺活检(MSGB)的相关性。

结果

pSS 组的 LGUS 实质分级为 0 级 14 例(16.5%),1 级 45 例(52.9%),2 级 23 例(27.1%),3 级 3 例(3.5%),对照组的实质分级为 0 级(57.1%)和 1 级(42.9%)。pSS 患者的 2D-SWE 值明显高于对照组(p<0.05),且与泪腺实质分级呈平行关系。弹性模量在检测 pSS 患者的泪腺受累方面具有较高的诊断性能(AUC 0.901,敏感性 70.6%,特异性 97.6%),而 LGUS 的诊断性能要低得多(AUC 0.769,敏感性 83.5%,特异性 57.1%)。LGUS 和 2D-SWE 值与干眼检查和 MSGB 结果相关(p<0.05)。

结论

LGUS 和 2D-SWE 均可用于评估 pSS 患者的泪腺受累情况;然而,2D-SWE 的诊断性能优于 LGUS,且与干眼检查结果相关。

临床意义

泪腺超声和二维剪切波弹性成像(2D-SWE)是可用于显示原发性干燥综合征(pSS)患者泪腺实质受累的影像学方法。

关键点

  • 灰阶超声和二维剪切波弹性成像(2D-SWE)在最近十年中被广泛用于评估原发性干燥综合征(pSS)患者的腺体受累情况。

  • 弹性模量在检测原发性干燥综合征(pSS)患者的泪腺受累方面具有较高的诊断性能。

  • LGUS 和 2D-SWE 均可用于评估原发性干燥综合征(pSS)患者的泪腺;然而,二维剪切波弹性成像(2D-SWE)的诊断性能优于泪腺超声(LGUS)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验