Suppr超能文献

Monitoring radiation exposure to medical personnel during percutaneous nephrolithotomy.

作者信息

Lowe F C, Auster M, Beck T J, Chang R, Marshall F F

出版信息

Urology. 1986 Sep;28(3):221-6. doi: 10.1016/0090-4295(86)90047-6.

Abstract

To ascertain radiation exposure to medical personnel during percutaneous nephrolithotomy, lithium fluoride thermoluminescent dosimeters (TLDs) were utilized for the radiographic monitoring of 7 consecutive patients. Average fluoroscopy time per procedure was 27.8 minutes of which 15.1 minutes were for nephrostomy tube insertion and 12.7 minutes were for calculi extraction. The 2 radiologists received 4.5 and 5.1 mrad per procedure, while the 2 urologists received 2.5 and 3.7 mrad. All other ancillary personnel received less than 2.1 mrad per procedure except the anesthesiologists whose mean exposure was 4.7 mrad. By taking appropriate precautions and using the proper equipment, percutaneous nephrolithotomy can be performed with a low level of radiation exposure for all involved physicians and personnel.

摘要