We aimed to evaluate the change in eyelid and ocular surface parameters that were measured using a digital measurement program, the change in the visual field (VF), and the correlation between ocular surface area (OSA) and VF parameters in patients who underwent upper eyelid blepharoplasty for involutional dermatochalasis.
Patients who underwent upper eyelid blepharoplasty for involutional dermatochalasis between August 2015 and August 2019 were included in the study. The difference between preoperative and postoperative 3rd month values of manually measured margin reflex distance 1 (MRD1), digitally measured eyelid and ocular surface parameters (MRD1, MRD 2 [MRD2], upper eyelid crease height [ECH], pretarsal show height [PTH], eyebrow line-height [EBH] and OSA), and VF parameters were evaluated. The correlation between preoperative and postoperative values of manually and digitally measured MRD1 and also preoperative and postoperative values of OSA and VF parameters were analyzed.
Thirty-six eyes from 36 patients were included in this study and the mean age of patients was 57.93±7.64 years. There were statistically significant changes between preoperative and postoperative values in means of the manually measured MRD1 and the digitally measured MRD1, PTH, OSA, and ECH (p<0.001). However, the postoperative changes in the mean MRD2 and EBH were not statistically significant (p=0.664 and p=0.983). There were moderate positive correlations between pre- and post-operative OSA values and pre- and postoperative values of manual and digital MRD1. A statistically significant agreement was observed between the change in OSA and the change in all VF parameters (Bland-Altman analysis test).
Digital measurements can be used to evaluate the changes in eyelid and ocular surface parameters in patients who underwent upper eyelid blepharoplasty surgery. OSA provides fast results in accordance with linear measurements and is compatible with the change in the VF.
我们旨在评估接受上睑皮肤松弛上睑成形术患者使用数字测量程序测量的眼睑和眼表参数的变化、视野(VF)的变化以及眼表面积(OSA)与VF参数之间的相关性。
纳入2015年8月至2019年8月期间因上睑皮肤松弛接受上睑成形术的患者。评估手动测量的缘反射距离1(MRD1)、数字测量的眼睑和眼表参数(MRD1、MRD 2 [MRD2]、上睑皱襞高度[ECH]、睑板前显露高度[PTH]、眉线高度[EBH]和OSA)以及VF参数术前和术后第3个月值的差异。分析手动和数字测量的MRD1术前和术后值之间以及OSA和VF参数术前和术后值之间的相关性。
本研究纳入了36例患者的36只眼,患者的平均年龄为57.93±7.64岁。手动测量的MRD1以及数字测量的MRD1、PTH、OSA和ECH的术前和术后均值之间存在统计学显著变化(p<0.001)。然而,平均MRD₂和EBH的术后变化无统计学意义(p=0.664和p=0.983)。术前和术后OSA值与手动和数字MRD1的术前和术后值之间存在中度正相关。在OSA变化与所有VF参数变化之间观察到统计学显著一致性(Bland-Altman分析检验)。
数字测量可用于评估接受上睑成形术患者的眼睑和眼表参数变化。OSA能根据线性测量快速得出结果,且与VF变化相符。