The purpose of this study was to quantify any differences between the SUVs of Zr immuno-PET scans obtained using a PET/CT system with a long axial field of view (LAFOV; Biograph Vision Quadra) compared to a PET/CT system with a short axial field of view (SAFOV; Biograph Vision) and to evaluate how LAFOV PET scan duration affects image noise and SUV metrics. Five metastatic breast cancer patients were scanned consecutively on SAFOV and LAFOV PET/CT scanners. Four additional patients were scanned using only LAFOV PET/CT. Scans on both systems lasted approximately 30 min and were acquired 4 d after injection of 37 MBq of Zr-trastuzumab. LAFOV list-mode data were reprocessed to obtain images acquired using shorter scan durations (15, 10, 7.5, 5, and 3 min). Volumes of interest were placed in healthy tissues, and tumors were segmented semiautomatically to compare coefficients of variation and to perform Bland-Altman analysis on SUV metrics (SUV, SUV, and SUV). Using 30-min images, 2 commonly used lesion SUV metrics were higher for SAFOV than for LAFOV PET (SUV, 16.2% ± 13.4%, and SUV, 10.1% ± 7.2%), whereas the SUV of healthy tissues showed minimal differences (0.7% ± 5.8%). Coefficients of variation in the liver derived from 30-min SAFOV PET were between those of 3- and 5-min LAFOV PET. The smallest SUV and SUV differences between SAFOV and LAFOV were found for 3-min LAFOV PET. LAFOV Zr immuno-PET showed a lower SUV and SUV than SAFOV because of lower image noise. LAFOV PET scan duration may be reduced at the expense of increasing image noise and bias in SUV metrics. Nevertheless, SUV showed only minimal bias when reducing scan duration from 30 to 10 min.
这项研究的目的是量化使用长轴向视野(LAFOV;Biograph Vision Quadra)和短轴向视野(SAFOV;Biograph Vision)的 PET/CT 系统获得的 Zr 免疫 PET 扫描的 SUV 之间的差异,并评估 LAFOV PET 扫描时间如何影响图像噪声和 SUV 指标。连续对 5 名转移性乳腺癌患者进行了 SAFOV 和 LAFOV PET/CT 扫描仪的扫描。另外 4 名患者仅使用 LAFOV PET/CT 进行了扫描。两种系统的扫描持续时间约为 30 分钟,在注射 37MBq Zr-曲妥珠单抗后 4 天进行。LAFOV 列表模式数据被重新处理,以获得使用较短扫描时间(15、10、7.5、5 和 3 分钟)获得的图像。在健康组织中放置感兴趣的体积,并半自动分割肿瘤,以比较变异系数,并对 SUV 指标(SUV、SUV 和 SUV)进行 Bland-Altman 分析。使用 30 分钟的图像,与 LAFOV PET 相比,SAFOV 的 2 种常用病变 SUV 指标更高(SUV,16.2%±13.4%和 SUV,10.1%±7.2%),而健康组织的 SUV 显示出最小的差异(0.7%±5.8%)。30 分钟的 SAFOV PET 衍生的肝脏变异系数介于 3 分钟和 5 分钟的 LAFOV PET 之间。在 LAFOV PET 中,最短 SUV 和 SUV 之间的差异发现为 3 分钟 LAFOV PET。由于图像噪声较低,LAFOV Zr 免疫 PET 的 SUV 和 SUV 低于 SAFOV。LAFOV PET 扫描时间可能会缩短,代价是增加图像噪声和 SUV 指标的偏差。然而,当将扫描时间从 30 分钟减少到 10 分钟时,SUV 仅显示出最小的偏差。