School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China.
Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, College of Veterinary Medicine, Yangzhou University, Yangzhou, 225002, PR China.
Talanta. 2024 Jan 1;266(Pt 1):125017. doi: 10.1016/j.talanta.2023.125017. Epub 2023 Aug 2.
Rapid and highly sensitive detection of tumor marker (TM) is critical for the early diagnosis and treatment of cancers. Herein, utilizing highly bright and water-stable CsPbBr perovskite nanocrystals (NCs) capped with amphiphilic polymer ligand of octylamine-modified polyacrylic acid (OPA) and gold nanoparticles (AuNPs) as reporters, a lateral flow immunoassay (LFIA) strip is developed for fluorescence and colorimetric dual-mode detection of carcinoembryonic antigen (CEA). The prepared CsPbBr NCs capped by an amphiphilic polymeric of OPA ligand showed high stability and bright fluorescence. Moreover, the AuNPs immunoprobes were captured with CEA antigen and quench the green fluorescence of CsPbBr/OPA NCs on the T line due to the inner filter effect (IFE). Therefore, CEA could be quantitative analyzed by the dual-readout of fluorescence and colorimetric signal. The detection limits of CEA can reach as low as 0.023 ng/mL and 0.027 ng/mL for the fluorescence and colorimetric mode, respectively. Good specificity and reproducibility were also demonstrated for this method. Finally, the CsPbBr3/OPA NCs-based LFIA showed good accuracy in detection of CEA level from clinical serum samples. This work firstly enables the application of CsPbBr perovskite NCs in a LFIA, displaying great potential in point-of-care clinical diagnosis.
快速且高灵敏度地检测肿瘤标志物 (TM) 对于癌症的早期诊断和治疗至关重要。在此,我们利用具有高亮度和高稳定性的 CsPbBr 钙钛矿纳米晶体 (NCs),其表面由两亲性聚合物配体辛胺修饰的聚丙烯酸 (OPA) 修饰,并负载金纳米粒子 (AuNPs) 作为报告分子,开发了侧向流动免疫分析 (LFIA) 试纸条,用于荧光和比色双模式检测癌胚抗原 (CEA)。所制备的 CsPbBr NCs 由两亲性聚合物 OPA 配体稳定包覆,表现出高稳定性和明亮的荧光。此外,由于内滤效应 (IFE),AuNPs 免疫探针与 CEA 抗原结合,并猝灭 T 线上 CsPbBr/OPA NCs 的绿色荧光。因此,CEA 可以通过荧光和比色信号的双重读取进行定量分析。荧光和比色模式下的 CEA 检测限分别低至 0.023 ng/mL 和 0.027 ng/mL。该方法还表现出良好的特异性和重现性。最后,基于 CsPbBr3/OPA NCs 的 LFIA 在检测临床血清样本中的 CEA 水平方面表现出良好的准确性。这项工作首次将 CsPbBr 钙钛矿 NCs 应用于 LFIA,在即时临床诊断方面显示出巨大的潜力。