Suppr超能文献

一种利用数字技术为开口受限患者制作外科阻塞器的改良技术。

A modified technique of using digital technology to fabricate surgical obturator in patients with limited mouth opening.

作者信息

Das Divyajoti, Gupta Rekha, Gill Shubhra, Saini Aishwarya

机构信息

Maulana Azad Institute of Dental Sciences, New Delhi, India.

The Department of Prosthodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India.

出版信息

J Oral Biol Craniofac Res. 2023 Sep-Oct;13(5):581-583. doi: 10.1016/j.jobcr.2023.06.007. Epub 2023 Jul 29.

Abstract

This article presents a digital technique for the fabrication of an immediate surgical obturator for a patient with decreased mouth opening planned for maxillectomy. The amalgamation of pre-operative Cone Beam Computed Tomography (CBCT) data and 3D printing allowed for the fabrication of the immediate surgical obturator without conventional pre-surgical diagnostic impression. The surgical obturator was placed in position intraorally post tumor resection to complete the obturation. The procedure followed led to an accurate fit of the prosthesis without any need for relining during surgery.

摘要

本文介绍了一种数字技术,用于为计划进行上颌骨切除术且张口受限的患者制作即刻外科阻塞器。术前锥形束计算机断层扫描(CBCT)数据与3D打印相结合,无需传统的术前诊断印模即可制作即刻外科阻塞器。肿瘤切除术后,将外科阻塞器经口放置到位以完成封闭。后续步骤使假体贴合准确,手术过程中无需重衬。