A program for a personal computer has been developed to calculate and optimize dose distributions around a high dose intracavitary afterloading applicator having a single source. The problems of the local irradiation of the endometrium-carcinoma are emphasized in connection with the optimization criteria for an adequate irradiation planing. Exemplarily, the anisotropic proportions of absorption around a special type of applicator are calculated. In addition, an algorithm for optimization of dwell times of three-dimensional arranged source positions according to a prescribed dose distribution is theoretically presented. Further, an easy way of finding isodosis by given source positions and dwell times is introduced by taking into consideration the need to superimpose the dose distribution with external radiation fields. All calculations are tested in a water phantom.

摘要

已开发出一种用于个人计算机的程序,以计算并优化具有单个源的高剂量腔内后装施源器周围的剂量分布。结合适当放疗计划的优化标准,强调了子宫内膜癌局部照射的问题。作为示例,计算了一种特殊类型施源器周围吸收的各向异性比例。此外,从理论上提出了一种根据规定剂量分布优化三维排列源位置驻留时间的算法。此外,考虑到需要将剂量分布与外照射野叠加,介绍了一种通过给定源位置和驻留时间来查找等剂量线的简便方法。所有计算均在水模体中进行了测试。