Abstract

The H295R test guideline assay evaluates the effect of test substances on synthesis of 17β-estradiol (E2) and testosterone (T). The objective of this study was to leverage commercial immunoassay technology to develop a more efficient H295R assay to measure E2 and T levels in 384-well format. The resulting Homogenous Time Resolved Fluorescence assay platform (H295R-HTRF) was evaluated against a training set of 36 chemicals derived from the OECD inter-laboratory validation study, EPA guideline 890.1200 aromatase assay, and azole fungicides active in the HT-H295R assay. Quality control performance criteria were met for all conditions except E2 synthesis inhibition where low basal hormone synthesis was observed. Five proficiency chemicals were active for both the E2 and T endpoints, consistent with guideline classifications. Of the nine OECD core reference chemicals, 9/9 were concordant with outcomes for E2 and 7/9 for T. Likewise, 9/13 and 11/13 OECD supplemental chemicals were concordant with anticipated effects for E2 and T, respectively. Of the 10 azole fungicides screened, 7/10 for E2 and 8/10 for T exhibited concordant outcomes for inhibition. Generally, all active chemicals in the training set demonstrated equivalent or greater potency in the H295R-HTRF assay, supporting the sensitivity of the platform. The adaptation of HTRF technology to the H295R model provides an efficient way to evaluate E2 and T modulators in accordance with guideline specifications.

摘要

H295R 测试指南测定法评估测试物质对 17β-雌二醇(E2)和睾酮(T)合成的影响。本研究的目的是利用商业免疫测定技术开发一种更有效的 H295R 测定法,以在 384 孔格式中测量 E2 和 T 水平。由此产生的均相时间分辨荧光测定平台(H295R-HTRF)针对来自 OECD 实验室间验证研究、EPA 指南 890.1200 芳香酶测定法和在 HT-H295R 测定法中有效的唑类杀真菌剂的 36 种化学物质的培训集进行了评估。除了观察到基础激素合成低的 E2 合成抑制外,所有条件均符合质量控制性能标准。五种能力验证化学物质对 E2 和 T 终点均具有活性,与指南分类一致。在 9 个 OECD 核心参考化学物质中,9/9 与 E2 的结果一致,7/9 与 T 的结果一致。同样,9/13 和 11/13 OECD 补充化学物质分别与 E2 和 T 的预期作用一致。在所筛选的 10 种唑类杀真菌剂中,7/10 对 E2 和 8/10 对 T 的抑制作用具有一致性结果。通常,培训集中所有活性化学物质在 H295R-HTRF 测定法中表现出等效或更高的效力,支持该平台的敏感性。HTRF 技术对 H295R 模型的适应为按照指南规范评估 E2 和 T 调节剂提供了一种有效的方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fbd8/10903741/518d1fb869c1/nihms-1965375-f0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验