Suppr超能文献

超声引导下经皮外周肺病变穿刺活检:系统评价和荟萃分析。

Ultrasound-guided core-needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis.

机构信息

Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, 637000, Nanchong, China.

Department of Ultrasound, Affiliated Hospital of North Sichuan Medical College, 637000, Nanchong, China.

出版信息

Clin Radiol. 2023 Oct;78(10):755-762. doi: 10.1016/j.crad.2023.07.005. Epub 2023 Jul 27.

Abstract

AIM

To evaluate the diagnostic value and safety of ultrasound-guided core-needle biopsy for peripheral pulmonary lesions (PPLs).

MATERIALS AND METHODS

PubMed, EMBASE, and the Cochrane Library for relevant were searched for studies published up to June 2022. The diagnostic accuracy of US-guided percutaneous transthoracic needle biopsy (PTNB) for the diagnosis of PPLs was evaluated using pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive and negative likelihood ratios (PLR and NLR), and the area under the summary receiver operating characteristic curves value (SROC).

RESULTS

The search included 12 original studies (3,830 procedures). For US-guided PTNB, the pooled sensitivity and specificity for the diagnosis of PPLs were 0.93 (95% confidence interval [CI]: 0.91-0.94) and 0.99 (95% CI: 0.96-1.00), respectively. The pooled estimates of the PLR, NLR, and DOR were 134.88 (95% CI: 24.88-731.74), 0.07 (95% CI: 0.06-0.09), and 1,814.95 (95% CI: 333.62-9,873.76), respectively. The area under the SROC curve was 0.95 (95% CI: 0.93-0.97). The overall complication rate was 3.6% (136 of 3,830), including self-limited haemoptysis and asymptomatic pneumothorax, and only six cases of pneumothorax requiring chest tube drainage and one case of severe bleeding were reported.

CONCLUSIONS

US-guided core-needle biopsy is an excellent diagnostic tool for PPLs, with high accuracy and excellent technical performance and safety.

摘要

目的

评估超声引导下经皮肺外周病变(PPL)穿刺活检的诊断价值和安全性。

材料与方法

检索截至 2022 年 6 月发表的相关文献,包括 PubMed、EMBASE 和 Cochrane 图书馆。采用汇总敏感度、特异度、诊断比值比(DOR)、阳性和阴性似然比(PLR 和 NLR)以及汇总受试者工作特征曲线下面积值(SROC)评价超声引导下经皮肺穿刺活检(PTNB)对 PPL 的诊断准确性。

结果

共纳入 12 项原始研究(3830 例操作)。对于超声引导下 PTNB,PPL 诊断的汇总敏感度和特异度分别为 0.93(95%置信区间[CI]:0.91-0.94)和 0.99(95% CI:0.96-1.00)。汇总的 PLR、 NLR 和 DOR 估计值分别为 134.88(95% CI:24.88-731.74)、0.07(95% CI:0.06-0.09)和 1814.95(95% CI:333.62-9873.76)。SROC 曲线下面积为 0.95(95% CI:0.93-0.97)。总体并发症发生率为 3.6%(3830 例中有 136 例),包括自限性咯血和无症状性气胸,仅报告 6 例气胸需胸腔引流,1 例严重出血。

结论

超声引导下穿刺活检是一种诊断 PPL 的优秀工具,具有高准确性、良好的技术性能和安全性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验