Larkin Spencer, Preston David
University of Kentucky College of Medicine and Veterans Affairs Medical Center (DP), Lexington, Kentucky.
Urol Pract. 2015 May;2(3):106-108. doi: 10.1016/j.urpr.2014.09.010. Epub 2015 Feb 24.
Ureteral stent placement is the main treatment for ureteral obstruction in contemporary urological practice. Meticulous followup is required to confirm ureteral stent removal. Forgotten ureteral stents create significant patient and physician risk. We assessed the efficacy of an electronic spreadsheet tracking system at a VA medical center urology practice to monitor ureteral stent placement and retrieval.
From January 2012 to February 2014 a computer based monitoring system was begun for all stents placed in our practice. An Excel® spreadsheet was used to track ureteral stent insertion and removal. The VA Computerized Patient Record System was used to confirm ureteral stent removal. The spreadsheet included an automatic calculator feature to alert technicians/surgeons when stents remained in place 180 days or longer.
In 335 patients a total of 379 stents were placed from January 2012 to February 2014. Of these 379 stents 369 were removed or exchanged in 180 days or less. Ten patients died with stents in place and were counted in the removal group for an overall 100% rate of stents accounted for/removed during the study period.
An electronic spreadsheet is an effective method to track ureteral stent placement and removal. Manual data entry, and frequent spreadsheet followup and monitoring contributed to a 100% retrieval rate in this study. Future efforts should focus on automated systems that generate reminders with less emphasis on human data entry and tracking.
在当代泌尿外科实践中,输尿管支架置入是治疗输尿管梗阻的主要方法。需要进行细致的随访以确认输尿管支架的取出情况。遗忘输尿管支架会给患者和医生带来重大风险。我们评估了一家退伍军人事务部(VA)医疗中心泌尿外科使用电子表格追踪系统监测输尿管支架置入和取出的效果。
从2012年1月至2014年2月,我们开始对本医疗机构置入的所有支架采用基于计算机的监测系统。使用Excel®电子表格来追踪输尿管支架的插入和取出情况。利用VA计算机化患者记录系统来确认输尿管支架的取出情况。该电子表格具有自动计算功能,当支架留置180天或更长时间时会提醒技术人员/外科医生。
在2012年1月至2014年2月期间,335例患者共置入379个支架。在这379个支架中,369个在180天或更短时间内被取出或更换。10例患者在支架留置的情况下死亡,这些患者被计入取出组,因此在研究期间支架的总体取出率为100%。
电子表格是追踪输尿管支架置入和取出的有效方法。人工数据录入以及频繁的电子表格随访和监测促成了本研究中100%的取出率。未来的工作应侧重于自动化系统,这些系统能生成提醒,减少对人工数据录入和追踪的依赖。