Suppr超能文献

比较两种常用多重检测方法在血清中测量微量营养素和炎症标志物的检测性能:南非孕妇调查结果。

Comparison of test performance of two commonly used multiplex assays to measure micronutrient and inflammatory markers in serum: results from a survey among pregnant women in South Africa.

机构信息

Division of Human Nutrition and Health, Wageningen University & Research, Wageningen, The Netherlands.

Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa.

出版信息

Br J Nutr. 2024 Jan 28;131(2):248-255. doi: 10.1017/S0007114523001782. Epub 2023 Aug 10.

Abstract

The combined sandwich-ELISA (s-ELISA; VitMin Lab, Germany) and the Quansys Q-Plex™ Human Micronutrient Array (7-Plex) are multiplex serum assays that are used to assess population micronutrient status in low-income countries. We aimed to compare the agreement of five analytes, -1-acid glycoprotein (AGP), C-reactive protein (CRP), ferritin, retinol-binding protein 4 (RBP4) and soluble transferrin receptor (sTfR) as measured by the 7-Plex and the s-ELISA. Serum samples were collected between March 2016 and December 2017. Pregnant women ( 249) were recruited at primary healthcare clinics in Johannesburg, and serum samples were collected between March 2016 and December 2017. Agreement between continuous measurements was assessed by Bland-Altman plots and concordance measures. Agreement in classifications of deficiency or inflammation was assessed by Cohen's kappa. Strong correlations (r > 0·80) were observed between the 7-Plex and s-ELISA for CRP and ferritin. Except for CRP, the 7-Plex assay gave consistently higher measurements than the s-ELISA. With the exception of CRP (Lin's ρ = 0·92), there was poor agreement between the two assays, with Lin's ρ < 0·90. Discrepancies of test results difference between methods increased as the serum concentrations rose. Cohen's kappa for all the five analytes was < 0·81 and ranged from slight agreement (vitamin A deficiency) to substantial (inflammation and Fe deficiency) agreement. The 7-Plex 1.0 is a research and or surveillance tool with potential for use in low-resource laboratories but cannot be used interchangeably with the s-ELISA. Further optimising and validation is required to establish its interchangeability with other validated methods.

摘要

夹心酶联免疫吸附测定法(s-ELISA;德国 VitMin Lab)和 QuanSys Q-PlexTM 人类微量营养素分析试剂盒(7 plex)是用于评估低收入国家人群微量营养素状况的多重血清检测方法。我们旨在比较这两种方法在测量 5 种分析物(-1-酸性糖蛋白(AGP)、C 反应蛋白(CRP)、铁蛋白、视黄醇结合蛋白 4(RBP4)和可溶性转铁蛋白受体(sTfR))时的一致性。血清样本采集于 2016 年 3 月至 2017 年 12 月。在约翰内斯堡的初级保健诊所招募了孕妇(249 名),血清样本采集于 2016 年 3 月至 2017 年 12 月。通过 Bland-Altman 图和一致性度量评估连续测量之间的一致性。通过 Cohen's kappa 评估缺乏或炎症分类的一致性。7-Plex 和 s-ELISA 之间观察到 CRP 和铁蛋白的强相关性(r > 0.80)。除 CRP 外,7-Plex 检测法的测量值始终高于 s-ELISA。除 CRP(Lin's ρ = 0.92)外,两种检测方法之间的一致性较差,Lin's ρ < 0.90。随着血清浓度的升高,检测结果差异的差异增加。所有 5 种分析物的 Cohen's kappa 均 < 0.81,范围从轻微一致性(维生素 A 缺乏)到显著一致性(炎症和 Fe 缺乏)。7-Plex 1.0 是一种研究和/或监测工具,具有在资源匮乏的实验室中使用的潜力,但不能与 s-ELISA 互换使用。需要进一步优化和验证才能确定其与其他经过验证的方法的互换性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c8f7/10751947/da931fa9746f/S0007114523001782_fig1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验