Suppr超能文献

女性会阴体的超声检查及其对盆底的支持功能研究

Ultrasonographic study of female perineal body and its supportive function on pelvic floor.

作者信息

Zhou Minzhi, Shui Wen, Bai Wenkun, Wu Xing, Ying Tao

机构信息

Department of Ultrasound in Medicine, Shanghai Institute of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.

出版信息

Front Med (Lausanne). 2023 Jul 26;10:1176360. doi: 10.3389/fmed.2023.1176360. eCollection 2023.

Abstract

OBJECTIVES

The study aimed to observe, measure the size and elastic value of perineal body (PB) and assess its association with levator hiatus.

METHODS

Datasets were acquired in 45 nulliparous, 66 POP women and 70 postpartum women using ultrasound. The PB was measured in depth, height, and Young's modulus. The datasets were compared to assess whether there are some differences in the morphology, dimension and elastography modulus of PB among women. Pearson correlation analysis was used to evaluate the association between the morphology measurements (ΔValsalva-rest[v-r]), tissue mechanical properties (ΔValsalva-rest[v-r]) of the PB and levator hiatus area (ΔValsalva-rest[v-r]) to preliminarily explore whether PB can influence levator hiatus.

RESULTS

Four representative manifestations of PB were presented in our study. Nulliparous women had smaller diameters and bigger Young's modulus while postpartum women had bigger diameters and smaller Young's modulus. POP and postpartum women had bigger levator hiatal distensibility and PB extensibility. There was no statistical association between PB measurements and levator hiatal area.

CONCLUSION

It is feasible to observe the morphology of PB and assess the dimension and elastography modulus by high-frequency ultrasound. The manifestations and measurements of PB are influenced by parity and long-term increased abdominal pressure. Our study preliminarily shows that PB has little effect on levator hiatus area.

摘要

目的

本研究旨在观察、测量会阴体(PB)的大小和弹性值,并评估其与提肌裂孔的关系。

方法

使用超声对45名未生育女性、66名盆腔器官脱垂(POP)女性和70名产后女性采集数据集。测量PB的深度、高度和杨氏模量。比较这些数据集,以评估不同女性之间PB的形态、尺寸和弹性成像模量是否存在差异。采用Pearson相关分析评估PB的形态测量值(瓦尔萨尔瓦动作-静息状态下的差值[v-r])、组织力学性能(瓦尔萨尔瓦动作-静息状态下的差值[v-r])与提肌裂孔面积(瓦尔萨尔瓦动作-静息状态下的差值[v-r])之间的关联,以初步探讨PB是否会影响提肌裂孔。

结果

本研究呈现了PB的四种代表性表现。未生育女性的直径较小,杨氏模量较大,而产后女性的直径较大,杨氏模量较小。POP女性和产后女性的提肌裂孔扩张性和PB伸展性较大。PB测量值与提肌裂孔面积之间无统计学关联。

结论

通过高频超声观察PB的形态、评估其尺寸和弹性成像模量是可行的。PB的表现和测量受产次和长期腹压增加的影响。我们的研究初步表明,PB对提肌裂孔面积影响较小。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9677/10410282/9a06a5da9ac1/fmed-10-1176360-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验