While Mpox virus (MPXV) diagnostics were performed in specialized laboratories only, the global emergence of Mpox cases in 2022 revealed the need for a more readily available diagnostic. Automated random-access platforms with fast nucleic acid extraction and PCR have become established in many laboratories, providing faster and more accessible testing. In this study, we adapted a previously published generic MPXV-PCR as a lab-developed test (LDT) on a NeuMoDx Molecular System and isolated MPXV clones from patient materials. To reduce the handling of infectious material, we evaluated a viral lysis buffer (VLB) for sample pretreatment. We further compared the MPXV-LDT-PCR to conventional real-time PCR, determined its sensitivity and specificity using positive swabs, and assessed its performance using external quality assessment samples. Pretreatment of samples with 50% VLB reduced MPXV infectivity by approximately 200-fold while maintaining PCR sensitivity. The assay demonstrated a sensitivity and specificity of 100% with no cross-reactivity in the samples tested and performed with a limit of detection of 262 GE/mL. In summary, the assay had a turnaround time of fewer than 2 h and can easily be transferred to other automated PCR platforms, providing a basis for developing rapid assays for upcoming pandemics.
虽然猴痘病毒 (MPXV) 的诊断仅在专业实验室进行,但 2022 年全球猴痘病例的出现表明需要更易于获得的诊断方法。具有快速核酸提取和 PCR 的自动化随机访问平台已在许多实验室中得到确立,提供了更快、更便捷的检测。在这项研究中,我们在 NeuMoDx 分子系统上对以前发表的通用 MPXV-PCR 进行了改编,作为实验室开发的测试 (LDT),并从患者材料中分离出 MPXV 克隆。为了减少处理传染性材料的次数,我们评估了一种病毒裂解缓冲液 (VLB) 用于样品预处理。我们进一步将 MPXV-LDT-PCR 与常规实时 PCR 进行比较,使用阳性拭子确定其灵敏度和特异性,并使用外部质量评估样本评估其性能。用 50% VLB 预处理样品可使 MPXV 感染性降低约 200 倍,同时保持 PCR 灵敏度。该检测方法在测试样本中无交叉反应,具有 100%的灵敏度和特异性,检测限为 262 GE/mL。总之,该检测方法的周转时间少于 2 小时,可以轻松转移到其他自动化 PCR 平台,为即将到来的大流行开发快速检测方法提供了基础。