Universitäts-Augenklinik Heidelberg, David J. Apple International Laboratory for Ocular Pathology und International Vision Correction Research Centre (IVCRC), Heidelberg, Deutschland.
Klin Monbl Augenheilkd. 2023 Aug;240(8):944-951. doi: 10.1055/a-2130-7503. Epub 2023 Aug 11.
Keratoconus is a bilateral, yet asymmetric disease. In rare cases, the second eye may show no signs of tomographic changes. The purpose of this study was to analyze the biomechanical characteristics in tomographically regular keratoconus fellow eyes.
This retrospective, consecutive case series analyzed 916 eyes of 458 patients who presented to our keratoconus clinic between November 2020 and October 2022. Primary outcome measures included best-corrected visual acuity (BCVA), tomographic Scheimpflug analysis using Pentacam AXL (Oculus, Wetzlar, Germany), and biomechanical assessment using Corvis ST (Oculus, Wetzlar, Germany). Tomographic changes were assessed via analysis of the anterior and posterior curvature, K-max, thinnest corneal thickness (TCT), the Belin/Ambrosio Deviation Display (BAD-D), and the ABCD-Grading. Biomechanical changes were analyzed using Corvis Biomechanical Index (CBI) and Tomographic Biomechanical Index (TBI).
Of 916 eyes, 34 tomographically regular fellow eyes (7.4%) were identified and included in the analysis. Overall, the mean BCVA was - 0.02 ± 0.13 logMAR. Tomographic analysis showed mean K-max of 43.87 ± 1.21 D, mean TCT of 532 ± 23 µm, and mean BAD-D of 1.02 ± 0.43. Biomechanical analysis demonstrated mean CBI of 0.28 ± 0.26 and mean TBI of 0.34 ± 0.30. While normal CBI-values were observed in 16 (47%) of 34 eyes, only 13 eyes (38%) showed a regular TBI and only 7 eyes (21%) showed regular TBI and CBI. The sensitivity of CBI and TBI to detect a tomographically normal keratoconus fellow eye was 53% and 62%, respectively.
A highly asymmetric corneal ectasia with regular tomographic finding in a fellow eye is rare among keratoconus patients. In such cases, a biomechanical analysis may be useful in detecting early signs of corneal ectasia. In our analysis, the TBI showed high sensitivity for detecting a biomechanical abnormality in tomographically regular fellow eyes.
圆锥角膜是一种双侧、但不对称的疾病。在极少数情况下,另一只眼可能没有明显的断层变化迹象。本研究的目的是分析在断层图像规则的圆锥角膜对侧眼中的生物力学特征。
本回顾性连续病例系列研究纳入了 2020 年 11 月至 2022 年 10 月期间在我们的圆锥角膜诊所就诊的 458 例患者的 916 只眼。主要观察指标包括最佳矫正视力(BCVA)、Pentacam AXL(Oculus,德国威茨拉尔)的断层Scheimpflug 分析和 Corvis ST(Oculus,德国威茨拉尔)的生物力学评估。通过分析前、后曲率、K-max、最薄角膜厚度(TCT)、Belin/Ambrosio 偏离显示(BAD-D)和 ABCD 分级评估断层变化。使用 Corvis 生物力学指数(CBI)和断层生物力学指数(TBI)分析生物力学变化。
在 916 只眼中,发现 34 只(7.4%)具有规则断层的对侧眼,并纳入分析。总体而言,平均 BCVA 为 -0.02±0.13 logMAR。断层分析显示平均 K-max 为 43.87±1.21 D,平均 TCT 为 532±23 µm,平均 BAD-D 为 1.02±0.43。生物力学分析显示平均 CBI 为 0.28±0.26,平均 TBI 为 0.34±0.30。在 34 只眼中,16 只(47%)的 CBI 值正常,只有 13 只眼(38%)的 TBI 正常,只有 7 只眼(21%)的 TBI 和 CBI 正常。CBI 和 TBI 检测圆锥角膜对侧眼正常断层的灵敏度分别为 53%和 62%。
在圆锥角膜患者中,对侧眼出现高度不对称性角膜扩张伴规则断层的情况非常罕见。在这种情况下,生物力学分析可能有助于早期发现角膜扩张。在我们的分析中,TBI 对检测对侧眼规则断层的生物力学异常具有较高的灵敏度。