Effective pressure management for individuals is critical for hospital and community-based care, to prevent the occurrence of pressure ulcers. This study explores the impact of a new mattress and topper solution on interface pressure and comfort during supine lying.
In this quantitative, healthy cohort study, patient-surface interface pressures were calculated for three mattresses (a standard hospital mattress, a new mattress solution (Levitex Foams Ltd., UK) and a dynamic air flow mattress) with and without an innovative topper solution (Levitex Foams Ltd., UK). Subjective comfort, contact surface area, peak and mean pressure and peak pressure index (head, sacrum, heels) were calculated for all mattress conditions for a 21-minute period.
A total of 27 healthy volunteers took part in this study. The new mattress solution decreased peak pressure significantly compared with the hospital and air mattresses (p<0.04). Lower peak pressures were observed for the hospital mattress compared with the dynamic air flow mattress. The new mattress solution improved comfort and significantly lowered (>30%; p≤0.005) heel and head pressure compared with the other surfaces. Both hospital and air mattresses significantly reduced pressure and improved comfort with the addition of the new topper solution (p<0.05).
The new mattress solution used in this study offers a potentially improved pressure management solution for individuals. Implementation of the topper may also help to improve pressure management when used with existing standard or dynamic air flow mattresses.
对个体进行有效的压力管理对于医院和社区护理至关重要,可预防压疮的发生。本研究探讨了新型床垫和床垫衬垫对仰卧位时的界面压力和舒适度的影响。
在这项定量的健康队列研究中,计算了三种床垫(标准医院床垫、新型床垫解决方案(英国 Levitex Foams Ltd.)和动态气流床垫)在使用和不使用创新床垫衬垫(英国 Levitex Foams Ltd.)时的患者-表面界面压力。对于所有床垫条件,计算了 21 分钟内的主观舒适度、接触表面积、峰值和平均压力以及峰值压力指数(头部、骶骨、脚跟)。
共有 27 名健康志愿者参加了这项研究。与医院和空气床垫相比,新型床垫解决方案显著降低了峰值压力(p<0.04)。与动态气流床垫相比,医院床垫的峰值压力更低。新型床垫解决方案改善了舒适度,并显著降低了脚跟和头部压力(降低>30%;p≤0.005),与其他表面相比。在添加新型床垫衬垫后,医院和空气床垫均显著降低了压力并改善了舒适度(p<0.05)。
本研究中使用的新型床垫解决方案为个体提供了一种潜在的压力管理解决方案。在使用现有标准或动态气流床垫时,衬垫的实施也有助于改善压力管理。