在小儿肝移植的定期随访中,剪切波弹性成像和剪切波频散与活检结果相关。

Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow-up of pediatric liver grafts.

作者信息

Cetinic Ivan, de Lange Charlotte, Boström Håkan, Ekvall Nils, Bennet William, Lagerstrand Kerstin, Hebelka Hanna

机构信息

Department of Pediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden.

Institution of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

出版信息

Pediatr Transplant. 2023 Nov;27(7):e14591. doi: 10.1111/petr.14591. Epub 2023 Aug 15.

Abstract

BACKGROUND

It is unknown how shear wave dispersion (SWD) is displayed in pediatric liver transplant recipients and not fully elucidated how ultrasound shear wave elastography (2D-SWE) display within this cohort, which is important to determine to improve noninvasive surveillance of these patients. The study aimed to compare SWE and SWD values with histopathology in pediatric liver recipients.

METHODS

Forty-eight pediatric liver recipients were examined with SWE in conjunction with an elective liver biopsy (clinically without complication). Additionally, SWD values were measured in 21 children. SWE and SWD values were compared to histologically determined fibrosis graded as none-to-mild (F0-1) and moderate-to-severe (F2-4), and inflammation graded as low (grade 0-1) and high (grade 2-4).

RESULTS

Two children were excluded due to SWE IQR/median > 30% kPa. The mean age across 46 included patients was 10.9 years (range 1.4-18). The number of patients and median (range) SWE value (kPa) for each stage of fibrosis were: F0-1 [n = 23; 5.8 (3.2-16.1)], F2 [n = 22; 6.0 (4.5-25.9)], F3 [n = 1; 33.3], and F4 [n = 0]. Significantly higher SWE values and greater variability were registered in F2-4 vs. F0-1 (p = .05). Grade of fibrosis correlated weakly to SWE values (r = .3; p = .05), but not to SWD values (r = .2; p = .27). In patients with low-grade inflammation, median SWD was 13.7 m/s KHz (10.7-17.6). Only one patient had high-grade inflammation.

CONCLUSIONS

Uncomplicated transplanted liver grafts in a small pediatric cohort revealed slightly increased SWE and SWD values compared to previously reported values in healthy children. This likely reflect both the fibrotic and inflammatory elements in the grafts; however, other confounders impacting the liver's viscoelastic properties are also probable factors.

摘要

背景

目前尚不清楚剪切波频散(SWD)在小儿肝移植受者中的表现,也未完全阐明超声剪切波弹性成像(2D-SWE)在该队列中的表现,而这对于确定如何改善对这些患者的无创监测很重要。本研究旨在比较小儿肝移植受者的SWE和SWD值与组织病理学结果。

方法

对48例小儿肝移植受者进行SWE检查,并进行择期肝活检(临床无并发症)。此外,对21名儿童测量了SWD值。将SWE和SWD值与组织学确定的纤维化程度(分为无至轻度(F0-1)和中度至重度(F2-4))以及炎症程度(分为低度(0-1级)和高度(2-4级))进行比较。

结果

由于SWE四分位间距/中位数>30%kPa,两名儿童被排除。46例纳入患者的平均年龄为10.9岁(范围1.4-18岁)。每个纤维化阶段的患者数量和SWE值中位数(范围)(kPa)分别为:F0-1[n=23;5.8(3.2-16.1)],F2[n=22;6.0(4.5-25.9)],F3[n=1;33.3],F4[n=0]。F2-4组的SWE值明显高于F0-1组,且变异性更大(p=0.05)。纤维化程度与SWE值弱相关(r=0.3;p=0.05),但与SWD值无关(r=0.2;p=0.27)。在低度炎症患者中,SWD中位数为13.7m/s KHz(10.7-17.6)。只有一名患者有高度炎症。

结论

在一小群小儿患者中,未发生并发症的移植肝移植物与先前报道的健康儿童的值相比,SWE和SWD值略有增加。这可能反映了移植物中的纤维化和炎症成分;然而,其他影响肝脏粘弹性特性的混杂因素也可能是原因。