子宫输卵管造影术中的辐射剂量降低:扫描束数字X线摄影的应用

Radiation dose reduction during hysterosalpingography: an application of scanning-beam digital radiography.

作者信息

Kushner D C, Yoder I C, Cleveland R H, Herman T E, Goodsitt M M

出版信息

Radiology. 1986 Oct;161(1):31-3. doi: 10.1148/radiology.161.1.3763882.

Abstract

Hysterosalpingography was performed in 31 patients by means of a low-dose scanning-beam digital radiographic system. The technique permits adequate evaluation of gynecologic abnormalities while allowing significant reduction in radiation: 2.4-mR (6.1 X 10(-7) C/kg) exposure to the skin and 0.7-mrad (7 X 10(-6) Gy) mean dose to the ovaries per image obtained. Sixteen patients demonstrated readily recognizable and documented abnormalities, corroborated by laparoscopy, laparotomy, or other supportive evidence.

摘要

采用低剂量扫描束数字放射成像系统对31例患者进行了子宫输卵管造影。该技术在显著减少辐射剂量的同时,能够充分评估妇科异常情况:每次成像时,皮肤的辐射暴露量为2.4毫伦琴(6.1×10⁻⁷库仑/千克),卵巢的平均剂量为0.7毫拉德(7×10⁻⁶戈瑞)。16例患者表现出易于识别且有记录的异常情况,经腹腔镜检查、剖腹手术或其他支持性证据得以证实。