Suppr超能文献

配位化学在反兴奋剂分析中的应用:高效液相色谱-高分辨串联质谱法测定乙二胺二硫代氨基甲酸盐络合钴

Coordination chemistry applied to anti-doping analysis: Cobalt quantification as its diethyldithiocarbamate complex by liquid chromatography coupled to high resolution tandem mass spectrometry.

机构信息

Laboratório Brasileiro de Controle de Dopagem, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.

Laboratório de Química Inorgânica Computacional, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.

出版信息

Drug Test Anal. 2023 Nov-Dec;15(11-12):1392-1402. doi: 10.1002/dta.3571. Epub 2023 Aug 28.

Abstract

Cobalt was included on the World Anti-Doping Agency Prohibited List in 2015 due to its effect on stimulus of erythropoiesis via stabilization of hypoxia-inducible factor. Although it has proven benefits for performance enhancement, the unavailability of inductively coupled plasma-mass spectrometry on routine of the accredited laboratories is a factor that reduces its applicability in anti-doping analysis. Therefore, an analytical method for quantification of urinary cobalt as its diethyldithiocarbamate complex by liquid chromatography coupled with high-resolution tandem mass spectrometry was developed and validated. Palladium was proposed as internal standard and rhodium as a complexation control. A microwave-assisted acid digestion of the urine samples was essential, not only to eliminate the matrix effect but mainly to avoid the non-specific bond of cobalt to endogenous molecules. A linear method was obtained over the studied range from a negative urine control to a spiked concentration of 25 ng/mL, with an estimated limit of quantification of 2.5 ng/mL, and an adequate combined standard uncertainty of 11.4%. Considering that all reagents are commercially available, the proposed strategy is feasible to be included on routine sample preparation. Monitoring urinary cobalt concentrations globally opens the perspective to support the anti-doping system to define a suitable threshold value and to understand its potential misuse by athletes seeking for performance improvement.

摘要

由于钴通过稳定缺氧诱导因子对红细胞生成的刺激作用,2015 年被世界反兴奋剂机构列入禁用清单。虽然它在提高运动表现方面有明显的好处,但由于认可实验室的常规检测中无法使用电感耦合等离子体质谱,这一因素降低了它在反兴奋剂分析中的适用性。因此,开发并验证了一种通过液相色谱-高分辨串联质谱法测定尿中钴与其二乙二硫代氨基甲酸盐络合物的定量分析方法。钯被提议作为内标,铑作为络合控制。微波辅助酸消解尿液样品是必不可少的,这不仅可以消除基质效应,而且主要可以避免钴与内源性分子的非特异性结合。研究范围内,从阴性尿液对照到 25ng/mL 的加标浓度,采用线性方法进行测定,估计定量限为 2.5ng/mL,综合标准不确定度为 11.4%。考虑到所有试剂均为市售产品,因此该策略可行,可纳入常规样品制备。监测全球尿钴浓度为支持反兴奋剂系统确定合适的阈值并了解运动员为提高成绩而潜在滥用提供了可能性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验