Scientific and Regulatory Affairs, Japan Tobacco Inc., Minato-Ku, Tokyo, Japan.
Clin Pharmacol Drug Dev. 2024 Jan;13(1):45-57. doi: 10.1002/cpdd.1322. Epub 2023 Sep 7.
This was a randomized, controlled, open-label, confinement study to assess change in exposure to selected cigarette smoke constituents in healthy adult cigarette smokers who switched to using a novel heated tobacco product (direct heating tobacco system, platform 3, generation 3, version a [DT3.0a]). Sixty nonmenthol cigarette smokers were randomized into 1 of the 4 study groups in which subjects switched to a nonmenthol type of tobacco stick used with DT3.0a, switched to a nonmenthol tobacco stick used with an in-market heated tobacco product device (THS), continued to smoke nonmenthol cigarettes, or stopped smoking. Furthermore, 30 menthol cigarette smokers were randomized into 1 of the 2 study groups in which subjects switched to a menthol tobacco stick used with DT3.0a (mDT3.0a) or continued to smoke menthol cigarettes. Fifteen biomarkers of exposure to selected harmful and potentially harmful constituents (HPHCs) were measured during the 5-day exposure period, followed by assessment of nicotine pharmacokinetics with the assigned product. Results indicated that switching to DT3.0a, THS, and mDT3.0a showed significant exposure reductions in most of the selected HPHCs as compared to continuing smoking cigarettes, with reductions being similar in magnitude to reductions observed with smoking cessation. For DT3.0a and mDT3.0a, nicotine pharmacokinetic parameters were not remarkably different from those obtained for cigarettes and the THS except that a longer time to maximum concentration was obtained following use of the mDT3.0a. In conclusion, switching from smoking cigarettes to DT3.0a or THS use reduced exposure to most of the selected HPHCs, and no remarkable differences were observed for the measurements obtained from different flavors of DT3.0a stick.
这是一项随机、对照、开放性、限入研究,旨在评估健康成年吸烟人群在改用新型加热烟草产品(直接加热烟草系统,第三代平台,a 版[DT3.0a])后,对选定香烟烟雾成分暴露量的变化。60 名非薄荷醇香烟吸烟者被随机分为 4 个研究组中的 1 个,其中受试者改用与 DT3.0a 一起使用的非薄荷醇型烟草棒、改用与市售加热烟草产品设备(THS)一起使用的非薄荷醇烟草棒、继续吸食非薄荷醇香烟或停止吸烟。此外,30 名薄荷醇香烟吸烟者被随机分为 2 个研究组中的 1 个,其中受试者改用与 DT3.0a 一起使用的薄荷醇烟草棒(mDT3.0a)或继续吸食薄荷醇香烟。在 5 天暴露期内,测量了 15 种选定有害和潜在有害成分(HPHC)的暴露生物标志物,然后评估了指定产品的尼古丁药代动力学。结果表明,与继续吸烟相比,改用 DT3.0a、THS 和 mDT3.0a 可显著降低大多数选定的 HPHC 暴露量,降低幅度与戒烟观察到的降低幅度相似。对于 DT3.0a 和 mDT3.0a,尼古丁药代动力学参数与香烟和 THS 获得的参数没有显著差异,除了使用 mDT3.0a 后达到最大浓度的时间更长。总之,从吸烟改为使用 DT3.0a 或 THS 可降低对大多数选定的 HPHC 的暴露,并且从不同口味的 DT3.0a 棒获得的测量值没有明显差异。