Suppr超能文献

循环载荷下全瓷前牙冠的断裂概率和寿命计算——一项有限元分析研究。

Computation of the fracture probability and lifetime of all ceramic anterior crowns under cyclic loading - An FEA study.

作者信息

Liu Chao, Eser Atilim, Heintze Siegward, Rothbrust Frank, Broeckmann Christoph

机构信息

IWM, RWTH-Aachen, Augustinerbach 4, D-52062 Aachen, Germany.

Research & Development, Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein.

出版信息

Dent Mater. 2023 Nov;39(11):965-976. doi: 10.1016/j.dental.2023.08.173. Epub 2023 Sep 9.

Abstract

OBJECTIVES

To predict the lifetime and fracture probability of anterior crowns made of a lithium disilicate glass-ceramic (IPS e.max CAD, LD, Ivoclar Vivadent, Liechtenstein) and a zirconia-containing lithium silicate glass-ceramic (Celtra Duo, ZLS, Dentsply Sirona, USA) under cycling loading.

METHODS

Three-point bending tests were conducted to measure the viscoelastic parameters. These parameters are used to compute the residual stresses of the anterior crown after crystallization. In the next analysis, the cyclic loading on the anterior crown was calculated. Based on this combined stress state (residual stress and stress state due to external cyclic loading), the life cycle and fracture probability of the anterior crown was calculated using the CARES/Life software. Finally, fatigue experiments were carried out to compare and validate the results of the computations.

RESULTS

Although a sound qualitative comparison of the lifetime of both materials can be done using this methodology, the calculated fracture probability of the anterior crown for both materials was very low in comparison with the fatigue test results using the fatigue parameters determined from the experiments. In order to achieve good correspondence with the experimental results, the SCG exponent n for both materials should be modified by a correlation factor of 0.38.

SIGNIFICANCE

Using this modified computational strategy, the results of the time-consuming fatigue tests for dental glass-ceramics can be closely predicted. This methodology can be integrated into the development process of new glass-ceramic materials in order to save time and costs.

摘要

目的

预测由二硅酸锂玻璃陶瓷(IPS e.max CAD,LD,义获嘉伟瓦登特公司,列支敦士登)和含氧化锆的硅酸锂玻璃陶瓷(Celtra Duo,ZLS,登士柏西诺德公司,美国)制成的前牙冠在循环加载下的寿命和断裂概率。

方法

进行三点弯曲试验以测量粘弹性参数。这些参数用于计算结晶后前牙冠的残余应力。在接下来的分析中,计算前牙冠上的循环载荷。基于这种组合应力状态(残余应力和外部循环加载引起的应力状态),使用CARES/Life软件计算前牙冠的生命周期和断裂概率。最后,进行疲劳试验以比较和验证计算结果。

结果

尽管使用这种方法可以对两种材料的寿命进行合理的定性比较,但与使用从实验确定的疲劳参数进行的疲劳试验结果相比,两种材料的前牙冠计算出的断裂概率都非常低。为了与实验结果取得良好的对应关系,两种材料的SCG指数n应通过0.38的相关因子进行修正。

意义

使用这种改进的计算策略,可以密切预测牙科玻璃陶瓷耗时的疲劳试验结果。这种方法可以整合到新型玻璃陶瓷材料的开发过程中,以节省时间和成本。