Abstract

PURPOSE

The study aimed to assess the accuracy of the FY-L formula in calculating intraocular lens (IOL) power after small-incision lenticule extraction (SMILE).

METHODS

For the post-SMILE IOL calculation of the same eye, the IOL power targeting the pre-SMILE eyes' lowest myopic refractive error was used. The FY-L formula, the Emmetropia Verifying Optical Formula (EVO-L), the Barrett True-K no history, and the Shammas-L, respectively, were used to calculate the predicted refractive error of target IOL power. A comparison was made between the change in spherical equivalent induced by SMILE (SMILE-Dif) and the variance between IOL-Dif (IOL-Induced Refractive Error) before and after SMILE. The prediction error (PE) was defined as SMILE-Dif minus IOL-Dif. The proportion of eyes with PEs within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D, the numerical and absolute prediction errors (PEs and AEs), and the median absolute error (MedAE) were compared.

RESULTS

In total, 80 eyes from 42 patients who underwent SMILE were included in the study. The FY-L formula generated the sample's lowest mean PE (0.06 ± 0.76 D), MAE (0.58 ± 0.50 D), and MedAE (0.47 D), respectively. The PEs in ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D comprised 28.8%, 46.3%, 70.0%, and 87.5%, respectively, for the FY-L formula. Compared to other formulas, the FY-L formula produced the highest value with PEs for the percentage of eyes in ±0.50 D, ±0.75 D, and ±1.00 D.

CONCLUSION

This study demonstrates that the FY-L formula provides satisfactory outcomes in estimating the IOL power in the eyes after SMILE.

摘要

目的

本研究旨在评估FY-L公式在小切口透镜切除术(SMILE)后计算人工晶状体(IOL)屈光度方面的准确性。

方法

对于同一只眼睛的SMILE术后IOL计算,使用以SMILE术前眼睛最低近视屈光不正为目标的IOL屈光度。分别使用FY-L公式、正视化验证光学公式(EVO-L)、Barrett True-K无病史公式和Shammas-L公式来计算目标IOL屈光度的预测屈光不正。比较了SMILE引起的等效球镜度变化(SMILE-Dif)与SMILE前后IOL-Dif(IOL诱导的屈光不正)之间的差异。预测误差(PE)定义为SMILE-Dif减去IOL-Dif。比较了PE在±0.25 D、±0.50 D、±0.75 D和±1.00 D范围内的眼睛比例、数值和绝对预测误差(PEs和AEs)以及中位数绝对误差(MedAE)。

结果

本研究共纳入42例接受SMILE手术患者的80只眼睛。FY-L公式分别产生了样本中最低的平均PE(0.06±0.76 D)、MAE(0.58±0.50 D)和MedAE(0.47 D)。对于FY-L公式,PE在±0.25 D、±0.50 D、±0.75 D和±1.00 D范围内的眼睛分别占28.8%、46.3%、70.0%和87.5%。与其他公式相比,FY-L公式在±0.50 D、±0.75 D和±1.00 D范围内的眼睛PE百分比产生了最高值。

结论

本研究表明,FY-L公式在估计SMILE术后眼睛的IOL屈光度方面提供了令人满意的结果。