Int J Prosthodont. 2023 Sep 12;36(4):443-450. doi: 10.11607/ijp.7183.
To evaluate the dimensional discrepancy between the diagnostic wax-up and the resulting mock-up.
A maxillary model with misaligned teeth was scanned, and an initial cast was 3D printed. A total of 60 identical casts were 3D printed from the initial one after scanning. Based on a digital additive veneer wax-up on the six anterior teeth, 10 more casts were 3D printed. The specimens were allocated to seven groups (n = 10) as follows-group 1: transparent silicone matrix with a flowable light-cured composite resin; group 2: same as group 1 but with the addition of a prefabricated transparent tray; group 3: silicone impression putty (65 Shore A) and light-body silicone impression material with a dual-cured bisacryl resin; group 4: same as group 3 but without the light-body silicone; group 5: silicone laboratory putty (92 Shore A) with a dual-cured bisacryl resin; group 6: silicone laboratory putty (92 Shore A) with PMMA; group 7: wax-up casts (control). Scans from the mock-ups were coregistered, segmented, and superimposed with the scans from the wax-up. The difference between the mock-up and the wax-up was quantified by morphologic operations. Results were analyzed by Kruskal-Wallis test and Dunn post hoc test (P < .05).
All mock-ups were larger than the wax-up. Significant differences were found for every labial surface third. The incisal third was the least accurate third while the middle third the most accurate. The most accurate were groups 2 and 5, and the largest discrepancy was observed in group 6.
The analog mock-up differs dimensionally from the wax-up, regardless of the technique/materials used.
评估诊断蜡型与最终代型之间的尺寸差异。
扫描有错位牙齿的上颌模型,并 3D 打印初始模型。从初始模型扫描后共打印了 60 个相同的模型。基于六个前牙的数字附加贴面蜡型,又打印了 10 个模型。将标本分为 7 组(n = 10),如下:组 1:带可流动光固化复合树脂的透明硅基质;组 2:与组 1 相同,但添加了预制透明托盘;组 3:硅印模膏(65 肖氏 A)和带双固化双丙烯酸树脂的轻体硅印模材料;组 4:与组 3 相同,但无轻体硅印模材料;组 5:带双固化双丙烯酸树脂的 92 肖氏 A 级硅实验室印模膏;组 6:带 PMMA 的 92 肖氏 A 级硅实验室印模膏;组 7:蜡型代型(对照)。从代型上进行扫描并进行配准、分割,然后与蜡型扫描进行叠加。通过形态学操作来量化代型和蜡型之间的差异。结果采用 Kruskal-Wallis 检验和 Dunn 事后检验(P <.05)进行分析。
所有代型均大于蜡型。每个唇面三分之一都存在显著差异。切缘三分之一是最不准确的三分之一,而中间三分之一是最准确的三分之一。最准确的是组 2 和组 5,而组 6 的差异最大。
无论使用的技术/材料如何,模拟代型与蜡型在尺寸上都存在差异。