Semiquantitative culturing of catheter tips has been used as an index of catheter-related bacteremia. As the sensitivity and predictive values of this test have not been determined, we studied 780 tips from central vein catheters inserted into 440 critically ill patients in an intensive care unit. The results were correlated with clinical data for 30 bacteremic episodes which occurred in these patients, 14 of which were catheter related. When five or more colonies per plate were taken as a positive result, the sensitivity of the method was 92%, and the specificity was 83%. Although the predictive value of a negative result was excellent (99.8%), the predictive value of a positive result was low (8.8%) in our patient population, which had a relatively low incidence of catheter-related bacteremia (2%). We conclude that a semiquantitative culture technique is useful in the diagnosis of bacteremia associated with central vein catheters.
导管尖端的半定量培养已被用作导管相关菌血症的一个指标。由于该检测的敏感性和预测价值尚未确定,我们对重症监护病房中440例重症患者所插入中心静脉导管的780个尖端进行了研究。结果与这些患者发生的30次菌血症发作的临床数据相关,其中14次与导管有关。当每平板有五个或更多菌落被视为阳性结果时,该方法的敏感性为92%,特异性为83%。尽管阴性结果的预测价值极佳(99.8%),但在我们的患者群体中,阳性结果的预测价值较低(8.8%),该群体中导管相关菌血症的发生率相对较低(2%)。我们得出结论,半定量培养技术在诊断与中心静脉导管相关的菌血症方面是有用的。