Suppr超能文献

测量单冠的近中接触以评估邻间间隙:一项初步研究。

Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study.

作者信息

Kim Daniel S, Lau Le Na, Kim Jong-Woong, Yeo In-Sung Luke

机构信息

Private Practice, Vancouver, WA, the United States.

Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Korea.

出版信息

Heliyon. 2023 Sep 22;9(10):e20403. doi: 10.1016/j.heliyon.2023.e20403. eCollection 2023 Oct.

Abstract

BACKGROUND

It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear.

OBJECTIVE

To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician.

METHODS

This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05.

RESULTS

In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant ( = 0.802 for mesial contacts,  = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact.

CONCLUSIONS

Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved.

摘要

背景

在制作单冠时,牙科技师在模型上调整相邻牙齿的邻面是常见操作。然而,若省略这一步骤,邻面接触的准确性是否会受到影响尚不清楚。

目的

评估由四种不同修复材料制作的下颌第一磨牙单冠的邻面接触准确性,且实验室/牙科技师不调整相邻牙齿的邻面。

方法

本研究为体外研究;所有临床操作均在牙模型上进行。使用金刚砂车针和高速手机对牙模型上的下颌第一磨牙进行预备。制作20个单冠,每组5个(全瓷氧化锆、二硅酸锂、金属陶瓷和铸造金)。在牙科实验室中,未对与最终冠相邻的邻面进行紧密接触调整。使用牙线和薄垫片进行定性分析,并使用立体显微镜进行定量分析,以评估修复体与相邻牙齿邻面接触的准确性。在定量分析中,采用单因素方差分析比较均值,显著性水平为0.05。

结果

在定量分析中,四组的邻面接触紧密性差异无统计学意义(近中接触:F = 0.802;远中接触:F = 0.354)。在定性分析中,大多数冠中,牙线穿过接触时阻力较大,且相邻牙齿与修复体之间只能插入一张薄垫片。然而,铸造金冠的一个样本存在接触开放情况。

结论

即使在冠制作过程中不对相邻牙齿的邻面进行调整,修复体与相邻牙齿之间也能实现足够的邻面接触紧密性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3f7c/10520794/0c5000705016/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验