Department of Prosthodontics and Crown and Bridge, Dr. Harvansh Singh Judge Institute of Dental Sciences, Chandigarh, India.
J Indian Prosthodont Soc. 2023 Jan-Mar;23(1):21-29. doi: 10.4103/jips.jips_218_22.
The aim of this study was to evaluate and compare the accuracy of hexed and nonhexed pickup impression copings with and without splinting using polyether (PE) and polyvinyl siloxane (PVS) impression materials in open-tray technique in recording multiple straight and angulated implant positions.
An accurate impression results in an accurate definitive cast, thus minimizing the incidence of prosthesis misfit. The critical aspect is to record the three-dimensional location of the implant in bone rather than reproducing fine surface details. Precise fit of a fixed implant-supported prosthesis depends on the accuracy of the implant analog location within the definitive cast. Factors which affect impression accuracy include implant angulation, impression material, impression copings, technique, and splinting.
A sample size of 80 study models fabricated from the impression of different groups was included. A reference master model based on All-on-4 implant concept with two parallel (implants 1 and 2) and two angulated (implant 3 at 17° and implant 4 at 30°) was fabricated using implant angulation guide. All impressions were recorded using open-tray impression technique. The groups were divided into two main groups of 40 samples each. Group A used hexed open-tray impression copings and Group B used nonhexed open-tray impression copings. Both the groups involved impression recording using splinted (Subgroup I) and nonsplinted impression copings (Subgroup II). Further, impressions in each subgroup were made using PE (Subsubgroups a) and PVS (Subsubgroup b). A total of eight subsubgroups with ten samples each were included. Impressions were recorded for each group and poured into Type IV die stone for fabrication of study models. After 24 h, the study models and reference master model were fitted with implant abutments for measurement with coordinate measuring machine.
The mean differences of the interimplant distance R1 (1-2), R2 (1-3), R3 (2-4), and R4 (3-4) between the reference model and sample models in different subsubgroups were calculated and three-way analysis of variance test was applied with Tukey's post hoc tests.
No significant difference was found in mean coronal deviations for distance R1, R2, and R3 (P > 0.05) between different study groups. P = 0.02 for R4 (distance between 17° and 30° implants) between impression materials subsubgroups suggested that significantly less distortion was created in location of highly angulated implants (>30°) using PVS impression material. Splinting and type of coping did not have a significant influence on impression accuracy. Increasing angulation decreased the accuracy.
PVS was found equivalent in accuracy to rigid PE for recording parallel or angulated implants. Impressions of implants with higher angulations were recorded more accurately with PVS. The study found no difference in accuracy with or without splinting. Furthermore, nonhexed impression copings facilitate easier and accurate recording of multiple angulated implant location in bone.
本研究旨在评估和比较使用聚醚(PE)和聚硅氧烷(PVS)印模材料在开放式托盘技术中,带有和不带有夹板的六边和非六边取模印模台在记录多个直型和角度种植体位置时的准确性。
准确的印模可获得准确的最终模型,从而最大限度地减少修复体适配不良的发生率。关键是记录种植体在骨中的三维位置,而不是复制精细的表面细节。固定种植体支持修复体的精确拟合取决于最终模型中种植体模拟位置的准确性。影响印模准确性的因素包括种植体角度、印模材料、取模印模台、技术和夹板。
从不同组的印模中制作了 80 个研究模型样本。使用种植体角度引导器制作了一个基于 All-on-4 种植体概念的参考主模型,该模型有两个平行(种植体 1 和 2)和两个角度(种植体 3 为 17°,种植体 4 为 30°)。所有印模均采用开放式托盘印模技术记录。将样本分为两组,每组 40 个样本。A 组使用六边开放式托盘取模印模台,B 组使用非六边开放式托盘取模印模台。两组均涉及有夹板(亚组 I)和无夹板(亚组 II)记录印模。此外,每组的印模分别使用 PE(亚亚组 a)和 PVS(亚亚组 b)进行记录。每个亚组有 10 个样本,共 8 个亚组。为每个组记录印模并倒入 IV 型铸造石中制作研究模型。24 小时后,研究模型和参考主模型与种植体基台适配,使用坐标测量机进行测量。
计算参考模型和不同亚组样本模型之间的种植体间距离 R1(1-2)、R2(1-3)、R3(2-4)和 R4(3-4)的平均差异,并应用三因素方差分析检验和 Tukey 事后检验。
不同研究组之间,R1、R2 和 R3(P > 0.05)的冠向偏差平均值无显著差异。R4(17°和 30°种植体之间的距离)的 P = 0.02 表明,在使用 PVS 印模材料时,对高度角度(>30°)的种植体位置产生的变形明显较小。夹板和取模印模台的类型对印模精度没有显著影响。角度增加会降低准确性。
PVS 在记录平行或角度种植体方面与刚性 PE 一样准确。使用 PVS 记录具有更高角度的种植体时,记录更准确。本研究发现,有无夹板对精度没有影响。此外,非六边取模印模台更便于准确记录多个角度的种植体在骨中的位置。