The aim of this study was to compare bioelectrical impedance analysis (BIA) with dual-energy X-ray absorptiometry (DXA) and investigate the accuracy of BIA in assessing appendicular skeletal muscle mass (ASM) and diagnosing sarcopenia. A total of 90 elderly patients hospitalized in the Affiliated Hospital of Hangzhou Normal University from 2019 to 2020 were collected, including 42 males and 48 females. All patients underwent BIA and DXA examinations. Pearson correlation and Bland-Altman analysis were used to compare the differences between BIA and DXA in assessing ASM and diagnosing sarcopenia. ASM measured by BIA was higher than ASM measured by DXA, and there was statistical significance for all differences (P < .001); Pearson correlation analysis showed that ASM measured by BIA and DXA was positively correlated in both male (R = 0.94) and female (R = 0.97) patients (P < .001); Bland-Altman analysis showed that there was a high consistency between ASM detected by BIA and DXA; The detection rate of low muscle mass and sarcopenia by BIA and DXA was not statistically significant (P > .05). BIA (InBody720) has high accuracy in assessing ASM and diagnosing sarcopenia in hospitalized Chinese older adults, and has the advantages of convenient use, no radiation, and easy promotion, so it can be used as an early screening tool in primary hospitals lacking DXA.

摘要

本研究旨在比较生物电阻抗分析(BIA)与双能 X 射线吸收法(DXA),并探讨 BIA 评估四肢骨骼肌质量(ASM)和诊断肌少症的准确性。共纳入 2019 年至 2020 年在杭州师范大学附属医院住院的 90 例老年患者,其中男 42 例,女 48 例。所有患者均接受 BIA 和 DXA 检查。采用 Pearson 相关和 Bland-Altman 分析比较 BIA 和 DXA 评估 ASM 和诊断肌少症的差异。BIA 测量的 ASM 高于 DXA 测量的 ASM,所有差异均有统计学意义(P <.001);Pearson 相关分析显示,男性(R = 0.94)和女性(R = 0.97)患者 BIA 和 DXA 测量的 ASM 呈正相关(P <.001);Bland-Altman 分析显示,BIA 和 DXA 检测的 ASM 之间具有高度一致性;BIA 和 DXA 检测的低肌肉量和肌少症的检出率无统计学差异(P >.05)。BIA(InBody720)在评估中国住院老年患者 ASM 和诊断肌少症方面具有较高的准确性,具有使用方便、无辐射、易于推广等优点,因此可作为缺乏 DXA 的基层医院的早期筛查工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5b5a/10545164/812211b69342/medi-102-e35250-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验