Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Liège, Bd de Colonster 20, 4000 Liège, Belgium (Burnotte, Gommeren, Kennedy, Merveille); Department of Veterinary Clinical and Diagnostic, Faculty of Veterinary Medicine, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4 (Boysen).
Can Vet J. 2023 Oct;64(10):951-956.
To compare left atrial measurements carried out by an emergency and critical care (ECC) clinician on cats in lateral and sternal recumbency.
A prospective observational study was conducted between December 2019 and January 2021 at the university teaching hospital at University of Liège. One hundred and two hospitalized cats were enrolled. Focused cardiac ultrasound (FOCUS) was performed in right lateral and sternal recumbency by a single FOCUS-trained ECC resident. Standard right parasternal long- and short-axis views were recorded. After randomization of the cineloops, the same blinded resident measured maximal left atrial dimension (LAD) and the ratio of left atrial to aortic diameter (LA:Ao). Reproducibility was assessed using the Bland-Altman method.
The LA:Ao and LAD measurements in lateral (LA:Ao median: 1.37, range: 1.02 to 3.22; LAD median: 13.25, range: 7.90 to 32.90) and sternal (LA:Ao median: 1.38, range: 1.06 to 3.22; LAD median: 13.00, range: 8.00 to 32.90) recumbency were not significantly different (bias: -0.003, CI -0.014, 0.007; and bias: -0.101, CI -0.231, 0.029, respectively).
The FOCUS technique was successfully applied in sternal recumbency in almost all cats. The LAD and LA:Ao measured in sternal and lateral recumbency were not significantly different. Cardiac left atrial measurements obtained using FOCUS can be reliably assessed in sternal recumbency in hospitalized, stable cats.
比较急诊和危重病学(ECC)临床医生在猫左侧卧位和胸骨旁卧位进行左心房测量的结果。
这是一项 2019 年 12 月至 2021 年 1 月在列日大学教学医院进行的前瞻性观察研究。共纳入 102 例住院猫。由一名经过 Focus 培训的 ECC 住院医师在右侧卧位和胸骨旁卧位进行 Focus 心脏超声检查(FOCUS)。记录标准的右胸骨旁长轴和短轴视图。在 cineloops 随机化后,同一名盲法住院医师测量最大左心房尺寸(LAD)和左心房与主动脉直径比(LA:Ao)。使用 Bland-Altman 方法评估可重复性。
左侧卧位(LA:Ao 中位数:1.37,范围:1.02 至 3.22;LAD 中位数:13.25,范围:7.90 至 32.90)和胸骨旁卧位(LA:Ao 中位数:1.38,范围:1.06 至 3.22;LAD 中位数:13.00,范围:8.00 至 32.90)的 LA:Ao 和 LAD 测量值无显著差异(偏倚:-0.003,CI -0.014,0.007;偏倚:-0.101,CI -0.231,0.029)。
FOCUS 技术在几乎所有猫的胸骨旁卧位中都成功应用。胸骨旁卧位和左侧卧位的 LAD 和 LA:Ao 无显著差异。在住院、稳定的猫中,使用 FOCUS 获得的心脏左心房测量值可以在胸骨旁卧位中可靠评估。