Suppr超能文献

巩膜瓣固定眼内人工晶状体时有效晶状体位置、倾斜和偏心的影响因素:模型眼研究。

CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS: A Model Eye Study.

机构信息

Keimyung University School of Medicine, Daegu, South Korea.

Seoul Balgeunsesang Eye Clinic, Seoul, South Korea.

出版信息

Retina. 2024 Feb 1;44(2):324-332. doi: 10.1097/IAE.0000000000003960.

Abstract

PURPOSE

The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography.

METHODS

Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180° apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope.

RESULTS

The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation ( P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length ( P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180° apart, the IOL may become decentered and tilted ( P < 0.01 and P < 0.05, respectively).

CONCLUSION

In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.

摘要

目的

作者旨在使用眼前节光学相干断层扫描(OCT)阐明巩膜固定型人工晶状体(IOL)带有翼缘的襻技术在人工眼球模型中与有效晶状体位置、倾斜和偏心相关的因素。

方法

两根弯曲的 27 号针头穿过 1.0 或 2.0mm 的巩膜隧道,距角膜缘后 2.0mm 且相距 180°。将三件式 IOL 的两个襻与导针对接并外露。使用眼前节 OCT 和立体显微镜分析与 IOL 位置相关的因素。

结果

1.0mm 的巩膜隧道比 2.0mm 的隧道和缝线固定引起的有效晶状体位置显著更长(P<0.05 和 P<0.01)。巩膜隧道长度的差异导致光学偏心到嵌入较短隧道的襻对侧和垂直于固定轴倾斜更大(P<0.001 和 P<0.05)。如果两个襻的巩膜固定点不完全相距 180°,则 IOL 可能会偏心和倾斜(P<0.01 和 P<0.05)。

结论

在翼缘襻技术中,巩膜隧道的长度、平衡和位置决定了 IOL 的有效晶状体位置、倾斜和偏心。