Department of Plastic & Reconstructive Surgery, Beaumont Hospital, Beaumont, Dublin, Ireland.
Department of Plastic & Reconstructive Surgery, Mater Misericordiae University Hospital, Dublin, Ireland.
Surgeon. 2024 Feb;22(1):60-66. doi: 10.1016/j.surge.2023.10.001. Epub 2023 Oct 21.
Data on the incidence, management, and consequences of retained microsurgical needles in plastic and reconstructive surgery remains sparse. Research suggests that a mobile C-arm x-ray has a low detection rate for needles of size 8-0 or smaller. By means of a literature review, and survey, we aimed to investigate the current practice employed in the event of the intraoperative loss of a microsurgical needle. A literature review was conducted investigating the incidence, current management strategies, and consequences of retained microsurgical needles. This informed the questions included in a survey investigating management strategies employed in the intra-operative loss of a microsurgical needle. Results from the literature review show an overall low detection rate of microsurgical needles on imaging. Of the forty responders who completed the survey, 80% did not use a mobile C-arm x-ray to locate a missing microsurgical needle. Of the 20% that had done so, x-ray had been unsuccessful in locating the needle in all cases. Portable x-ray has a definite role to play in locating needles of size 7-0 or larger. This study suggests that suture needles of size 8-0 or smaller cannot be reliably detected on x-ray. Regarding management of this event, one should consider the risk of harm to the patient if retained, against the risk of searching for the needle. Based on the results of this work as well as existing published data, we advise against obtaining intra-operative x-rays in the event of a lost needle size 8-0 and above. Appropriate documentation should be completed.
关于在整形和重建外科手术中遗留显微手术针的发生率、处理方法和后果的数据仍然很少。研究表明,移动 C 臂 X 射线对 8-0 或更小尺寸的针的检测率较低。通过文献回顾和调查,我们旨在研究术中丢失显微手术针时目前采用的实践。
文献回顾调查了遗留显微手术针的发生率、当前的管理策略和后果。这为调查术中丢失显微手术针时采用的管理策略的调查问卷提供了问题。文献回顾的结果显示,影像学上对显微手术针的总体检测率较低。在完成调查的四十名答复者中,80%的人不使用移动 C 臂 X 射线来定位丢失的显微手术针。在使用过 X 射线的 20%的人中,X 射线在所有情况下都未能定位到针。便携式 X 射线在定位 7-0 或更大尺寸的针方面确实有一定的作用。本研究表明,8-0 或更小尺寸的缝线针不能可靠地在 X 射线上检测到。关于这种情况的处理,应该考虑如果遗留下来对患者造成伤害的风险,与寻找针的风险相权衡。基于这项工作的结果以及现有的已发表数据,我们建议在丢失 8-0 及以上尺寸的针的情况下不要进行术中 X 射线检查。应完成适当的记录。