Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Professor, Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tennessee, USA.
J Esthet Restor Dent. 2024 Apr;36(4):573-587. doi: 10.1111/jerd.13158. Epub 2023 Oct 30.
To provide a 3-year follow-up of previously treated patients to assess and compare the periodontal responses and clinical performance of proximal subgingival open sandwich restorations.
Ninety-five adults participated in the study, with a combined total of 120 compound Class II cavities. These cavities had gingival margins located below the CEJ. Four different restorative materials were used to elevate the dentin/cementum gingival margins of the cavities: resin-modified glass ionomer, glass hybrid, flowable bulk-fill composite, or ion-releasing material, which were then completed with the same overlaying composite. Different periodontal and clinical evaluations, based on the criteria set by the World Dental Federation (FDI) criteria, were performed at different time intervals, including baseline, 6 months, 1, 2, and 3 years.
The type of base material did not affect the periodontal evaluations. There were no statistically significant differences between different time intervals or base material groups in any of the evaluated FDI parameters. However, the ion-releasing material scored significantly worse in the radiographic evaluation than any of the other groups.
All tested materials are suitable for proximal subgingival open sandwich restorations, as long as the restoration/tooth margin is at least 2-mm away from the bone crest.
Clinicians can confidently choose any of the tested materials for proximal subgingival open sandwich restorations, as they have shown good outcomes from both periodontal and clinical perspectives.
对先前治疗过的患者进行 3 年随访,以评估和比较近中龈下开放式三明治修复体的牙周反应和临床性能。
95 名成年人参与了这项研究,共有 120 个复合 II 类洞。这些洞的龈缘位于 CEJ 以下。使用四种不同的修复材料来提升洞的牙本质/牙骨质龈缘:树脂改良型玻璃离子体、玻璃混合体、流动型大体积充填复合材料或离子释放材料,然后用相同的覆盖复合材料完成。根据世界牙科联合会(FDI)标准制定的不同牙周和临床评估标准,在不同时间间隔(基线、6 个月、1、2 和 3 年)进行评估。
基底材料的类型不影响牙周评估。在任何评估的 FDI 参数中,不同时间间隔或基底材料组之间均无统计学差异。然而,与其他组相比,离子释放材料在放射学评估中得分明显较差。
只要修复体/牙颈边缘距离骨嵴至少 2mm,所有测试材料均适用于近中龈下开放式三明治修复体。
只要修复体/牙颈边缘距离骨嵴至少 2mm,临床医生可以放心地选择任何一种测试材料进行近中龈下开放式三明治修复体,因为它们在牙周和临床方面都表现出了良好的效果。