Suppr超能文献

县级医院行 Exeter 骨水泥型全髋关节置换术的疗效:894 髋最少随访 10 年的生存率。

Outcomes of Exeter cemented total hip arthroplasty in a county hospital: survivorship of eight hundred and ninety four hips with a minimum ten-year follow up.

机构信息

Department of Orthopaedics, Saint George University Teaching and County Hospital Centre for Musculoskeletal Surgery, Székesfehérvár, Hungary.

Centre for Translational Medicine, Semmelweis University, Üllői Út 26, 1085, Budapest, Hungary.

出版信息

Int Orthop. 2024 Mar;48(3):729-735. doi: 10.1007/s00264-023-06026-y. Epub 2023 Nov 2.

Abstract

PURPOSE

A total of 894 hips were evaluated to describe the survivorship of Exeter cemented femoral stems and report the outcomes and complications of our 'Exeter- era', and there is no study from Central or Eastern Europe demonstrating similar results.

METHODS

Between January 2000 and December 2009, a total of 894 hips were included who underwent Exeter universal and V40 femoral stems with a mean follow up of 13 years. Cemented Exeter low profile polyethylene cups were used in 889 patients (99.4%) cups. Harris hip score (HHS) was used and statistical outcome measures were calculated with revision as an endpoint for aseptic loosening of the stem, aseptic loosening of any component, all-cause revision of the stem, and all-cause revision of the hip.

RESULTS

A total of 103 patients died and 129 (14.4%) operated hips were lost to follow-up before ten years. Out of the 662, ten stems (1.5%) were revised for aseptic loosening. Aseptic loosening of any component was the reason for revision in 43 cases (6.5%), consisting of 40 cup revisions and ten stem exchanges. Periprosthetic fracture occurred in 17 cases (1.9%) Periprosthetic joint infection occurred in 18 cases (2.01%). Three cups were exchanged for recurrent dislocation, and two stems had broken.

CONCLUSION

Exeter hip system has provided reproducible results across different centres worldwide, as it did in our series. Thorough surgical and cementing technique is of utmost importance for achieving these results. The cup is the weak point of the system and use of a hybrid system is worth considering.

摘要

目的

评估了 894 髋,以描述 Exeter 骨水泥股骨柄的存活率,并报告我们的“Exeter 时代”的结果和并发症,而来自中欧或东欧的研究尚无类似结果。

方法

2000 年 1 月至 2009 年 12 月,共纳入 894 髋,平均随访 13 年。889 例患者(99.4%)使用了带 Exeter 低轮廓聚乙烯杯的 Exeter 通用和 V40 股骨柄。使用 Harris 髋关节评分(HHS),以翻修为无菌性松动的终点,计算统计结果测量值,包括股骨柄、任何组件的无菌性松动、股骨柄的所有原因翻修和髋关节的所有原因翻修。

结果

共有 103 例患者死亡,129 例(14.4%)手术髋在 10 年前失访。在 662 例中,有 10 例(1.5%)股骨柄因无菌性松动而翻修。43 例(6.5%)因任何组件无菌性松动而翻修,包括 40 例杯翻修和 10 例柄置换。发生 17 例(1.9%)假体周围骨折,18 例(2.01%)发生假体周围关节感染。3 例因复发性脱位而更换髋臼,2 例柄断裂。

结论

Exeter 髋关节系统在全球不同中心都提供了可重复的结果,就像我们的系列研究一样。彻底的手术和骨水泥技术对于获得这些结果至关重要。髋臼是该系统的薄弱环节,使用混合系统值得考虑。