Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany; Translational Lung Research Center (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany; Department of Diagnostic & Interventional Radiology with Nuclear Medicine, Thoraxklinik at Heidelberg University Hospital, Heidelberg, Germany.
Divison of Radiology, German Cancer Research Center, Heidelberg, Germany.
Magn Reson Imaging. 2024 Jan;105:75-81. doi: 10.1016/j.mri.2023.11.004. Epub 2023 Nov 7.
To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T, T and T* mapping.
Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T, T, and T weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T measured by modified Look-Locker (MOLLI), T measured by variable flip angle (VFA), T measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T measured by radial turbo-spin-echo (rTSE) and T measured by multiple gradient echo (MGRE) sequences.
The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation.
The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T, T and T liver tissue characterization in a single breath-hold scan.
应用多-shot 高分辨率多反转自旋和梯度回波(MI-SAGE)采集技术,同时进行肝脏 T1、T2 和 T* mapping。
采用递增层面顺序的反转预备自旋和梯度回波 EPI 进行开发,以实现 T1、T2 和 T*加权的高效采集。多-shot EPI 也被实现,以最小化失真和模糊,同时实现高的平面内分辨率。字典匹配方法被用于将图像拟合到定量参数图中,这些参数图与通过改良 Look-Locker(MOLLI)测量的 T1、通过可变翻转角(VFA)测量的 T2、通过多回波时间半傅里叶单 shot 涡轮自旋回波(HASTE)测量的 T2、通过径向涡轮自旋回波(rTSE)测量的 T2 和通过多梯度回波(MGRE)序列测量的 T2 进行比较。
该序列的多-shot 变体在 28 秒内实现了更高的 1.7×1.7mm 的平面内分辨率和良好的图像质量。衍生的定量图显示与传统映射方法具有可比性的值。在体模和体内测量中,MOLLI、MESE 和 MGRE 与 MISAGE 给出最接近的值。VFA、HASTE 和 rTSE 显示明显的高估。
所提出的多-shot 反转预备自旋和梯度回波 EPI 序列允许在单次屏气扫描中进行高分辨率定量 T1、T2 和 T 肝脏组织特征描述。