Suppr超能文献

定量对比敏感度与视网膜静脉阻塞的广角扫频源光相干断层血管造影的相关性。

Associations of quantitative contrast sensitivity with wide-field swept-source optical coherence tomography angiography in retinal vein occlusion.

机构信息

Harvard Retinal Imaging Lab, Boston, MA, USA.

Retina Service, Massachusetts Eye and Ear, Boston, MA, USA.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2024 Mar;262(3):789-799. doi: 10.1007/s00417-023-06288-7. Epub 2023 Nov 13.

Abstract

PURPOSE

To investigate associations between contrast sensitivity (CS) and vascular metrics on wide-field swept-source optical coherence tomography angiography (WF-SS-OCTA) in patients with retinal vein occlusion (RVO).

METHODS

This prospectively recruited, cross-sectional observational study included RVO patients who underwent quantitative CS function (qCSF) testing and WF-SS-OCTA using 3 × 3, 6 × 6, and 12 × 12 mm angiograms on the same day. The study measured several qCSF outcomes and WF-SS-OCTA vascular metrics, including vessel density (VD), vessel skeletonized density (VSD), and foveal avascular zone (FAZ). The data were analyzed using multivariable regression analysis controlling for age and central subfield thickness (CST).

RESULTS

A total of 43 RVO eyes of 43 patients and 30 fellow eyes were included. In RVO eyes, multiple vascular metrics were associated with CS outcomes but not visual acuity (VA). On 12 × 12 images, CS thresholds at 1 cpd, 1.5 cpd, and 3 cpd were significantly associated with VD and VSD, but VA was not. When comparing standardized regression coefficients, we found that vascular metrics had a larger effect size on CS than on VA. For instance, the standardized beta coefficient for FAZ area and CS at 6 cpd (β* = - 0.46, p = 0.007) was larger than logMAR VA (β* = 0.40, p = 0.011).

CONCLUSION

Microvascular changes on WF-SS-OCTA in RVO had a larger effect size on CS than VA. This suggests CS may better reflect the microvascular changes of RVO compared to VA. qCSF-measured CS might be a valuable adjunct functional metric in evaluating RVO patients.

摘要

目的

研究在视网膜静脉阻塞(RVO)患者中,宽视野扫频源光学相干断层扫描血管造影(WF-SS-OCTA)的对比敏感度(CS)与血管指标之间的相关性。

方法

这是一项前瞻性招募的、横断面观察性研究,纳入了当天接受定量 CS 功能(qCSF)测试和 WF-SS-OCTA 的 RVO 患者。使用 3×3、6×6 和 12×12mm 血管造影图进行检查。该研究测量了几个 qCSF 结果和 WF-SS-OCTA 血管指标,包括血管密度(VD)、血管骨架密度(VSD)和黄斑无血管区(FAZ)。数据通过多变量回归分析进行分析,控制年龄和中央视网膜神经纤维层厚度(CST)。

结果

共纳入 43 例患者的 43 只 RVO 眼和 30 只对侧眼。在 RVO 眼中,多种血管指标与 CS 结果相关,但与视力(VA)无关。在 12×12 图像上,1 cpd、1.5 cpd 和 3 cpd 的 CS 阈值与 VD 和 VSD 显著相关,但与 VA 无关。当比较标准化回归系数时,我们发现血管指标对 CS 的影响大小大于对 VA 的影响。例如,FAZ 面积和 6 cpd 处 CS 的标准化β系数(β*=-0.46,p=0.007)大于 logMAR VA(β*=0.40,p=0.011)。

结论

RVO 患者 WF-SS-OCTA 上的微血管变化对 CS 的影响大于对 VA 的影响。这表明 CS 可能比 VA 更能反映 RVO 的微血管变化。qCSF 测量的 CS 可能是评估 RVO 患者的一种有价值的附加功能指标。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验