Nesvetov V N, Orlov M V, Radzevich A E, Besprozvannyĭ A B, Shpektor A V
Kardiologiia. 1986 Oct;26(10):69-72.
The practicability of using hydrogen peroxide solutions for contrast echocardiography was examined. The administration of 1-3 ml of 0.2% solution mixed with a drop of the patient's blood, into the cubital or catheterized subclavian vein produced intensive and lasting (up to 2 min) contrast of the right cavities of the heart. Cubital injection of the solution was associated with a more lasting effect, as compared to the subclavian administration. The causes of this difference are yet to be investigated. The contrasting effect was fairly persistent and marked even when concentrations of the hydrogen peroxide solutions were reduced to 0.15 or 0.1%. The rate of administration was not more than 1 ml/s and had no negative effect on the quality of the contrast. No side effects associated with repeated administration of 1-3 ml hydrogen peroxide solution in the above-mentioned concentrations were noted in either of the 20 patients thus examined.
研究了使用过氧化氢溶液进行超声心动图造影的可行性。将1 - 3毫升0.2%的溶液与一滴患者血液混合,注入肘静脉或经导管插入的锁骨下静脉,可使心脏右腔产生强烈且持久(长达2分钟)的造影效果。与锁骨下注射相比,肘静脉注射该溶液的效果更持久。这种差异的原因尚待研究。即使将过氧化氢溶液的浓度降至0.15%或0.1%,造影效果仍相当持久且显著。给药速度不超过1毫升/秒,对造影质量无负面影响。在接受检查的20例患者中,未观察到因重复注射上述浓度的1 - 3毫升过氧化氢溶液而产生的副作用。