School of Dental Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
School of Mechanical Engineering, College of Engineering, Universiti Teknologi MARA, Shah Alam, Selangor, Malaysia.
Proc Inst Mech Eng H. 2024 Jan;238(1):55-62. doi: 10.1177/09544119231212034. Epub 2023 Nov 22.
This study aimed to compare the 3D skull models reconstructed from computed tomography (CT) images using three different open-source software with a commercial software as a reference. The commercial Mimics v17.0 software was used to reconstruct the 3D skull models from 58 subjects. Next, two open-source software, MITK Workbench 2016.11, 3D Slicer 4.8.1 and InVesalius 3.1 were used to reconstruct the 3D skull models from the same subjects. All four software went through similar steps in 3D reconstruction process. The 3D skull models from the commercial and open-source software were exported in standard tessellation language (STL) format into CloudCompare v2.8 software and superimposed for geometric analyses. Hausdorff distance (HD) analysis demonstrated the average points distance of Mimics versus MITK was 0.25 mm. Meanwhile, for Mimics versus 3D Slicer and Mimics versus InVesalius, there was almost no differences between the two superimposed 3D skull models with average points distance of 0.01 mm. Based on Dice similarity coefficient (DSC) analysis, the similarity between Mimics versus MITK, Mimics versus 3D Slicer and Mimics versus InVesalius were 94.1, 98.8 and 98.3%, respectively. In conclusion, this study confirmed that the alternative open-source software, MITK, 3D Slicer and InVesalius gave comparable results in 3D reconstruction of skull models compared to the commercial gold standard Mimics software. This open-source software could possibly be used for pre-operative planning in cranio-maxillofacial cases and for patient management in the hospitals or institutions with limited budget.
本研究旨在比较三种不同的开源软件与商业软件(Mimics v17.0)重建的 CT 图像三维颅骨模型。使用商业软件 Mimics v17.0 从 58 名受试者中重建三维颅骨模型。然后,使用两种开源软件,MITK Workbench 2016.11、3D Slicer 4.8.1 和 InVesalius 3.1,从相同的受试者中重建三维颅骨模型。所有四种软件在三维重建过程中都经过了类似的步骤。商业软件和开源软件生成的三维颅骨模型以标准三角网格语言 (STL) 格式导出到 CloudCompare v2.8 软件中,并进行几何分析叠加。Hausdorff 距离(HD)分析表明 Mimics 与 MITK 的平均点距离为 0.25mm。同时,对于 Mimics 与 3D Slicer 和 Mimics 与 InVesalius,两个叠加的三维颅骨模型之间几乎没有差异,平均点距离为 0.01mm。基于骰子相似系数(DSC)分析,Mimics 与 MITK、Mimics 与 3D Slicer 和 Mimics 与 InVesalius 的相似度分别为 94.1%、98.8%和 98.3%。总之,本研究证实,替代开源软件 MITK、3D Slicer 和 InVesalius 在颅骨模型的三维重建方面与商业金标准 Mimics 软件相比,结果相当。这种开源软件可用于颅颌面手术的术前规划,以及在预算有限的医院或机构中对患者进行管理。