Department of Pediatrics, Shengjing Hospital of China Medical University, Shenyang City, 110004, Liaoning Province, People's Republic of China.
Department of Nursing, Shengjing Hospital of China Medical University, Shenyang, China.
BMC Pediatr. 2023 Dec 9;23(1):623. doi: 10.1186/s12887-023-04444-w.
In recent years, intracardiac electrocardiogram (IC-ECG) technology has been widely used for epicutaneo-cava catheter (ECC) placement and has shown many potential advantages. However, evidence about the quantitative changes, effectiveness, and safety of IC-ECG for lower extremity ECC is sparse. This study aimed to explore the quantitative changes in IC-ECG for lower extremity ECC and determine its effectiveness and safety.
A retrospective study was conducted on 303 premature infants who underwent successful IC-ECG-guided lower extremity ECC placement between January 2019 and December 2021. All patients underwent chest X-ray postoperatively to verify the position of the catheter tip. The amplitudes of the surface electrocardiogram and IC-ECG QRS waves and the difference between the two amplitudes were measured. The effectiveness (matching rate between IC-ECG and chest X-ray) and safety (incidence of catheter-related complications) of IC-ECG for lower extremity ECC were evaluated.
The matching rate between IC-ECG and chest X-ray was 95.0%. When the catheter tip was optimally positioned, the QRS amplitude of the IC-ECG was 0.85 ± 0.56 mv higher than that of the surface electrocardiogram. The overall incidence of catheter-related complications was 10.6%. The actual ECC insertion length was associated with a noticeably increased risk of catheter-related complications.
This study suggests that IC-ECG is an effective and safe method by observing the dynamic changes in both QRS complexes and P wave to locate the tip of lower extremity ECC in preterm infants. Our findings would facilitate the application of IC-ECG for ECC localization.
近年来,心内电图(IC-ECG)技术已广泛应用于经皮腔外导管(ECC)的放置,并显示出许多潜在的优势。然而,关于 IC-ECG 对下肢 ECC 的定量变化、有效性和安全性的证据仍然很少。本研究旨在探讨 IC-ECG 对下肢 ECC 的定量变化,并确定其有效性和安全性。
对 2019 年 1 月至 2021 年 12 月期间成功接受 IC-ECG 引导的下肢 ECC 放置的 303 例早产儿进行回顾性研究。所有患者术后均行胸部 X 线检查以验证导管尖端的位置。测量体表心电图和 IC-ECG QRS 波的幅度以及两者之间的差值。评估 IC-ECG 对下肢 ECC 的有效性(IC-ECG 与 X 线胸片的匹配率)和安全性(导管相关并发症的发生率)。
IC-ECG 与 X 线胸片的匹配率为 95.0%。当导管尖端位置最佳时,IC-ECG 的 QRS 波幅度比体表心电图高 0.85±0.56 mV。导管相关并发症的总发生率为 10.6%。实际 ECC 插入长度与导管相关并发症的风险明显增加有关。
本研究表明,通过观察 QRS 波群和 P 波的动态变化,IC-ECG 是一种有效且安全的方法,可定位早产儿下肢 ECC 的尖端。我们的研究结果将有助于 IC-ECG 在 ECC 定位中的应用。