Methods based on paper-based analytical devices (PAD) and smartphone photographic colorimetric detection have become representative instrument-independent point-of-care testing (POCT) platforms due to their low cost and simplicity. However, the detection of target components from whole blood sample still presents challenges in terms of field preparation of small amounts of blood sample and detection sensitivity. This paper presents a rapid online processing method for whole blood samples on PAD based on plasma separation membrane (PSM), and combined with electrokinetic stacking and selective chromatic reaction. Real-time smartphone-based colorimetric detection of free hemoglobin (FHb) and human serum albumin (HSA) was successfully demonstrated.

RESULTS

With the proposed method, both detections for low and high concentration analytes could be implemented. The limits of detection of 16.6 mg L for FHb and 0.67 g L for HSA were obtained, respectively, with RSD below 8 %. The reliability of the method was verified by the recovery test and desktop spectrophotometric method. The detection results for real blood samples were in agreement with that by clinical methods.

SIGNIFICANCE AND NOVELTY

The PAD method is inexpensive, simple and fast, and detection of a whole blood sample of 5 μL can be finished in 5 min. This work shows that POCT of biomarkers from whole blood with PAD is possible without using any desktop facilities.

摘要

背景

基于纸质分析器件(PAD)和智能手机照相比色检测的方法由于其低成本和简单性,已成为代表性的无仪器即时检测(POCT)平台。然而,由于小体积全血样本的现场制备和检测灵敏度等方面的挑战,仍难以实现对全血样本中目标成分的检测。本文提出了一种基于血浆分离膜(PSM)的 PAD 全血样本快速在线处理方法,并结合电动堆积和选择性显色反应。成功实现了游离血红蛋白(FHb)和人血清白蛋白(HSA)的实时智能手机比色检测。

结果

采用所提出的方法,可以实现对低浓度和高浓度分析物的检测。分别得到 FHb 的检测限为 16.6mg/L,HSA 的检测限为 0.67g/L,相对标准偏差(RSD)低于 8%。通过回收率试验和台式分光光度法验证了该方法的可靠性。实际血液样本的检测结果与临床方法一致。

意义和新颖性

该 PAD 方法成本低、简单、快速,可在 5 分钟内完成 5μL 全血样本的检测。这项工作表明,无需使用任何台式设备,使用 PAD 即可对全血中的生物标志物进行 POCT。