镰状细胞病患者血红蛋白测量中无创分光光度法与血液学分析的比较

Comparing Non-Invasive Spectrophotometry to Hematology Analysis for Hemoglobin Measurements in Sickle Cell Disease Patients.

作者信息

Yassen Khaled, Omer Nawal, Alsahaf Fatimah, Al Amer Fatima, Alhamad Fatimah, Alherz Imran, Bushehab Abdulaziz, Alniniya Fatma, Alwabari Maryam

机构信息

Anesthesia Unit, Surgery Department, College of Medicine, King Faisal University, Hofuf 31983, Al Ahsa, Saudi Arabia.

Hereditary Blood Disease Center, Hofuf 36422, Al Ahsa, Saudi Arabia.

出版信息

J Clin Med. 2023 Dec 5;12(24):7517. doi: 10.3390/jcm12247517.

Abstract

Patients with sickle cell disease (SCD) require repeated blood sampling for hemoglobin (Hb) concentration measurements. The primary aim of this study was to compare non-invasive spectrophotometric hemoglobin (SpHb, g/dL) measurements to those taken via an automated hematology analyzer (Hb, g/dL) in patients with SCD visiting outpatient clinics and to investigate the correlations and agreements between both measurement techniques. Secondarily, we aimed to identify the SpHb cut-off concentration for the diagnosis of anemia and to monitor the effects of the pleth variability index (PVI, %) and perfusion index (PI) on SpHb measurements. The results gained from the examination of one hundred and fifty-eight patients indicated that the SpHb measurements overestimated the lab Hb concentrations, with a mean (SpHb-Hb) bias of 0.82 g/dL (SD 1.29). The SpHb measurements were positively correlated with the Hb measurements (Kendall's tau correlation (τ), = 158, τ = 0.68, < 0.001), with an intra-class correlation (ICC) of 0.67 and a 95% CI from 0.57 to 0.74 ( = 0.000). The SpHb cut-off concentration to diagnose anemia was 11.4 and 11.7 g/dL for males and females, respectively. SpHb sensitivity was low for males and females at 64.4% and 57.1%; however, the specificity was higher at 90.9% and 75%, with positive predictive values (PPVs) of 95.6 and 85.7, respectively. No correlation existed between SpHb measurements and the PVI (%) in contrast with a moderate correlation with the PI (r = 0.049, = 0.54, and r = 0.36, < 0.001, respectively). The mean PI was low at 2.52 ± 1.7. In conclusion, the SpHb measurements were consistently higher than the lab Hb concentrations, with a positive correlation. The sensitivity and precision of the SpHb measurements were lower than expected. However, the SpHb specificity and its positive predictive values (PPVs) indicated that it is less likely for a patient with a positive SpHb test result for anemia to be non-anemic. These results will allow SpHb measurement to play a role in excluding the presence of anemia. In light of the low PI values determined, the SpHb measurements were challenging to take and, thus, require further technological improvements.

摘要

镰状细胞病(SCD)患者需要反复进行血液采样以测量血红蛋白(Hb)浓度。本研究的主要目的是比较门诊就诊的SCD患者的无创分光光度法血红蛋白(SpHb,g/dL)测量值与通过自动血液分析仪测得的Hb(g/dL)值,并研究两种测量技术之间的相关性和一致性。其次,我们旨在确定诊断贫血的SpHb临界浓度,并监测灌注变异指数(PVI,%)和灌注指数(PI)对SpHb测量值的影响。对158例患者的检查结果表明,SpHb测量值高估了实验室Hb浓度,平均(SpHb-Hb)偏差为0.82 g/dL(标准差1.29)。SpHb测量值与Hb测量值呈正相关(肯德尔tau相关性(τ),n = 158,τ = 0.68,P < 0.001),组内相关性(ICC)为0.67,95%置信区间为0.57至0.74(P = 0.000)。诊断男性和女性贫血的SpHb临界浓度分别为11.4 g/dL和11.7 g/dL。男性和女性的SpHb敏感性较低,分别为64.4%和57.1%;然而,特异性较高,分别为90.9%和75%,阳性预测值(PPV)分别为95.6和85.7。SpHb测量值与PVI(%)之间无相关性,而与PI呈中度相关性(r = 0.049,P = 0.54,和r = 0.36,P < 0.001)。平均PI较低,为2.52±1.7。总之,SpHb测量值始终高于实验室Hb浓度,呈正相关。SpHb测量值的敏感性和精密度低于预期。然而,SpHb的特异性及其阳性预测值表明,SpHb贫血检测结果为阳性的患者不太可能无贫血。这些结果将使SpHb测量在排除贫血存在方面发挥作用。鉴于所确定的PI值较低,SpHb测量具有挑战性,因此需要进一步的技术改进。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/97a5/10744205/a986362912b7/jcm-12-07517-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验