Suppr超能文献

创新的困难气道管理方法:使用 Cook®气道交换导管进行双腔管插管。

Innovative Approach to Difficult Airway Management: Utilizing the Cook® Airway Exchange Catheter for Double-Lumen Tube Intubation.

机构信息

Department of Anesthesiology, Centre Hospitalier Universitaire (CHU) UCL Namur, Yvoir, Belgium.

出版信息

Am J Case Rep. 2024 Jan 4;25:e942288. doi: 10.12659/AJCR.942288.

Abstract

BACKGROUND The Cook® Airway ExchangeCatheter (Cook® AEC, Cook Group Incorporated, Bloomington, Indiana, USA) is an 83-cm-long graduated hollow tube with an external diameter of 11, 14, or 19 French, commonly used for tracheal tube replacement. Although this application is reliable in the exchange of single-lumen tubes, the failure rate markedly rises during the exchange from a single-lumen to a double-lumen endotracheal tube. It is also often used as a bridge to extubation in patients with difficult airways and for oxygenation support applications. CASE REPORT We describe the case of a 58-year-old patient with unexpected difficult airway management. He was scheduled to undergo a minimally invasive hybrid esophagectomy (laparoscopic abdominal stage followed by an open right thoracotomy, requiring one-lung ventilation with a double-lumen tube). After the laparoscopic abdominal stage, performed with a single-lumen endotracheal tube, we exchanged it for a double-lumen endotracheal tube. After several unsuccessful exchanges with a Cook® Airway Exchange Catheter due to the flexibility of the exchange catheter, we decided to use the exchange catheter as a method to maintain adequate ventilation while using it as a target to facilitate tracheal intubation alongside it, using a videolaryngoscope. CONCLUSIONS This case report discusses an unusual use of the Cook® Airway ExchangeCatheter during videolaryngoscopic double-lumen endotracheal tube (DLT) intubation. It reviews previously documented uses in the literature, while highlighting the possibility of failure during tube exchange. It also highlights its value as a support for oxygenation and ventilation during difficult intubation attempts.

摘要

背景

Cook® Airway ExchangeCatheter(Cook® AEC,美国印第安纳州布鲁明顿的 Cook 集团公司)是一种 83 厘米长的渐变式中空管,外径为 11、14 或 19 French,通常用于更换气管导管。虽然这种应用在单腔管的交换中是可靠的,但在从单腔管到双腔气管内管的交换中,失败率显著上升。它也常用于作为困难气道患者拔管的桥梁,以及用于氧合支持应用。

病例报告

我们描述了一例 58 岁患者意外出现困难气道管理的病例。他计划接受微创杂交食管切除术(腹腔镜腹部阶段后行开放性右开胸术,需要使用双腔气管内管进行单肺通气)。在腹腔镜腹部阶段完成后,我们使用单腔气管内管进行了交换,随后我们试图使用 Cook® Airway Exchange Catheter 进行交换,但由于交换导管的柔韧性,交换导管交换了几次都失败了,我们决定将其用作维持充足通气的方法,同时将其用作引导气管内插管的目标,使用视频喉镜进行插管。

结论

本病例报告讨论了在视频喉镜双腔气管内管(DLT)插管过程中使用 Cook® Airway ExchangeCatheter 的一种不常见用途。它回顾了文献中记录的以前的用途,同时强调了在导管交换过程中可能失败的可能性。它还强调了在困难插管尝试期间作为氧合和通气支持的价值。