Feng Xuebin, Zhu Xueru, Zhu Mengyu, Qian Yan, Li Hua
College of Engineering, Nanjing Agricultural University, Nanjing, 210031, China.
Curr Microbiol. 2024 Jan 10;81(2):58. doi: 10.1007/s00284-023-03564-x.
The pulsed electric field (PEF) of μs duration can induce electroporation by causing permanent damage to the membrane, leading to cell death. The microbe was treated by a homemade PEF generator instrument. The sterilization effect of PEF on the Rhizoctonia solani was observed by scanning electron microscope (SEM) and transmission electron microscope (TEM), and the leakage of the intracellular contents was measured with a conductometer and an ultraviolet spectrophotometer. The increases in the electrical conductivity and the optical density (OD) value indicated that the cell membrane was damaged, and the intracellular contents overflowed. As a result, according to our experimental conditions, the optimum condition was the high-pulsed electric voltage of 26 kV, and the treatment time was 4 min. It could be concluded that the PEF could damage the cell membrane, and the ratio of electroporation reached 100%, which provides a new method of killing R. solani efficiently.
微秒级持续时间的脉冲电场(PEF)可通过对细胞膜造成永久性损伤来诱导电穿孔,从而导致细胞死亡。使用自制的PEF发生器仪器对微生物进行处理。通过扫描电子显微镜(SEM)和透射电子显微镜(TEM)观察PEF对立枯丝核菌的杀菌效果,并用导电仪和紫外分光光度计测量细胞内容物的泄漏情况。电导率和光密度(OD)值的增加表明细胞膜受到损伤,细胞内容物溢出。结果表明,根据我们的实验条件,最佳条件是26 kV的高脉冲电压,处理时间为4分钟。可以得出结论,PEF可损伤细胞膜,电穿孔率达到100%,这为高效杀灭立枯丝核菌提供了一种新方法。