Pathak Ankita, Dhamande Mithilesh M, Sathe Seema, Bhoyar Anjali, Gujjelwar Smruti
Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND.
Cureus. 2023 Dec 13;15(12):e50450. doi: 10.7759/cureus.50450. eCollection 2023 Dec.
The misplacement of implants represents an unfavorable complication in dental implant prostheses. Numerous instances necessitating restorative intervention, colloquially termed "rescue cases," encompass either novel occurrences or reconstructions of irreversible implant scenarios. A viable solution for addressing these prosthesis-related challenges is using cementable options. This issue is directly linked to improperly placed implants, which dentists find challenging to rectify due to the absence of angle-correcting abutments from manufacturers. In such situations, the preferred treatments involve either Implant Innovations' universal castable long abutment (UCLA) (Palm Beach Gardens, Florida, United States) or a customized abutment fashioned from the titanium alloy impression coping for the Core-Vent implant (Paragon, Calabasas, California, United States). The Department of Prosthodontics received a referral for a patient with an anterior implant that had been misplaced and required rehabilitation. This case report outlines the chosen treatment approach for an implant situated buccally.
种植体位置不当是牙种植修复中的一种不良并发症。许多需要修复干预的情况,通俗地称为“挽救病例”,包括新出现的情况或不可逆种植体情况的重建。解决这些与修复体相关挑战的一个可行解决方案是使用可粘结的选择。这个问题与种植体放置不当直接相关,由于制造商没有角度校正基台,牙医发现很难纠正这种情况。在这种情况下,首选的治疗方法是使用种植创新公司的通用可铸造长基台(UCLA)(美国佛罗里达州棕榈滩花园)或由用于Core-Vent种植体(美国加利福尼亚州卡拉巴萨斯的Paragon)的钛合金印模帽制成的定制基台。口腔修复科收到了一位前牙种植体位置不当且需要修复的患者的转诊。本病例报告概述了针对颊侧种植体所选择的治疗方法。