Abstract

We used electronic fluorography to perform hysterosalpingography in 25 women with infertility or abnormal bleeding. In contrast to the conventional modality of fluoroscopy with intermittent permanent imaging, an image intensifier was used to periodically record dye injection on a moving tape (cine hysterosalpingography). The mean number of electronic fluorographs taken per patient was 10.8 +/- 3.12 (mean +/- SD). The mean radiation exposure per patient for electronic fluorography was 113.4 +/- 52 versus 112 +/- 52.4 mR when a single conventional radiographic image was taken. We conclude that electronic fluorography is a simple yet accurate radiographic method that delivers to the gonads approximately one-eleventh the dose of ionizing radiation that current standard techniques do, and should be accepted as an alternative diagnostic modality.

摘要

我们使用电子荧光摄影术对25名患有不孕症或异常出血的女性进行子宫输卵管造影。与采用间歇性永久成像的传统荧光透视方式不同,我们使用影像增强器在移动磁带上定期记录造影剂注射情况(动态子宫输卵管造影)。每位患者拍摄的电子荧光照片平均数量为10.8±3.12(平均值±标准差)。电子荧光摄影术每位患者的平均辐射暴露量为113.4±52,而拍摄一张传统X光片时的平均辐射暴露量为112±52.4毫伦琴。我们得出结论,电子荧光摄影术是一种简单而准确的放射成像方法,其对性腺的电离辐射剂量约为当前标准技术的十一分之一,应被视为一种替代诊断方式。