Median Nerves' Electrical Activation Reduces Ipsilateral Brachial Arteries' Blood Flow and Diameter.

作者信息

Ege Fahrettin, Kazci Ömer

机构信息

Department of Neurology, VM Medicalpark Hospital, Ankara, Türkiye.

Department of Radiology, Ankara Training and Research Hospital, Ankara, Türkiye.

出版信息

Ann Indian Acad Neurol. 2023 Nov-Dec;26(6):883-888. doi: 10.4103/aian.aian_345_23. Epub 2023 Sep 25.

Abstract

PURPOSE

Our main objective in this study was to determine whether there is a difference between ipsilateral and contralateral brachial arteries' flow parameters in response to median nerves' electrical activation.

MATERIAL AND METHODS

The study was conducted in healthy and active subjects. The arterial diameter and flow were measured using the probe from the brachial artery. Then, the median nerve was stimulated for 5 seconds via the bipolar stimulus electrode. Arterial diameter and flow were measured once more with the Doppler transducer, which kept going to monitor continuously just after the fifth stimulus. After a week, the same subjects are invited for the purpose of measuring the contralateral brachial arteries' vasomotor response to the same stimulus.

RESULTS

Before electrical stimulation, the median flow rate was 72.15 ml/min; after stimulation, the median flow rate was 39.20 ml/min. The drop in flow after stimulation was statistically significant ( < 0.001). While the median value of brachial artery vessel diameter before median nerve stimulation in the entire study group was 3.50 mm, the median value of vessel diameter after stimulation was 2.90 mm. After stimulation, the median nerve diameter narrowed statistically significantly ( < 0.001). As for the contralateral brachial in response to the right median nerves' activation, no significant flow or diameter change was found ( = 0.600, = 0.495, respectively).

CONCLUSION

We discovered that electrical stimulation of the median nerve caused significant changes in ipsilateral brachial artery blood flow and diameter in healthy volunteers. The same stimulation does not result in flow parameter changes in the contralateral brachial artery.

摘要

目的

本研究的主要目的是确定在正中神经电刺激时,同侧和对侧肱动脉血流参数之间是否存在差异。

材料与方法

本研究在健康且活跃的受试者中进行。使用来自肱动脉的探头测量动脉直径和血流。然后,通过双极刺激电极对正中神经进行5秒的刺激。在第五次刺激后,使用多普勒换能器再次测量动脉直径和血流,该换能器会持续监测。一周后,邀请相同的受试者测量对侧肱动脉对相同刺激的血管舒缩反应。

结果

电刺激前,平均流速为72.15毫升/分钟;刺激后,平均流速为39.20毫升/分钟。刺激后血流下降具有统计学意义(<0.001)。在整个研究组中,正中神经刺激前肱动脉血管直径的中位数为3.50毫米,刺激后血管直径的中位数为2.90毫米。刺激后,正中神经直径在统计学上显著变窄(<0.001)。至于对侧肱动脉对右侧正中神经激活的反应,未发现血流或直径有显著变化(分别为=0.600,=0.495)。

结论

我们发现,在健康志愿者中,正中神经的电刺激会导致同侧肱动脉血流和直径发生显著变化。相同的刺激不会导致对侧肱动脉血流参数发生变化。