Dittman Lauren E, Munaretto Nicholas, Hinchcliff Katharine, Dutton Lauren, Kakar Sanjeev
Mayo Clinic, Rochester, MN, USA.
Hand (N Y). 2024 Jan 18:15589447231221168. doi: 10.1177/15589447231221168.
The NanoScope, given its smaller size, may be further from critical structures when establishing volar wrist arthroscopy portals compared to the traditional 2.7-mm arthroscope.
Ten fresh-frozen latex-injected cadaver specimens were utilized. The volar radial (VR) and volar ulnar (VU) portals were created using an inside-out approach. The volar radial midcarpal (VR-MC) and volar ulnar midcarpal (VU-MC) portals were created using an inside-out approach. The arm was then dissected under 3.5-mm loupe magnification. Digital calipers were used to measure the distance between the portals and the surrounding anatomic structures by two fellowship-trained hand surgeons.
The median nerve was on average 1.6, 7.2, 1.8, and 5.6 mm away from the trochar for the VR, VU, VR-MC, and VU-MC, respectively. The median nerve fascia was pierced by the VR portal in one specimen. The radial artery, ulnar artery, and ulnar nerve were not pierced in any specimen. Compared to historical controls, for the VR-MC portal, the NanoScope was further from all critical structures, aside from the radial artery, and did not pierce any neurovascular structures. For the VU-MC portal, the NanoScope was further from the ulnar artery and median nerve and did not pierce any neurovascular structures.
In developing volar portals, after placing the cannula through the volar capsule from an inside-out approach, we recommend making a volar incision and dissecting the local anatomic structures to guard against injury. Compared to historical controls, the NanoScope was typically further from neurovascular structures.
鉴于其尺寸较小,与传统的2.7毫米关节镜相比,在建立掌侧腕关节镜入路时,纳米关节镜可能离关键结构更远。
使用10个新鲜冷冻并注入乳胶的尸体标本。采用由内向外的方法建立桡侧掌侧(VR)和尺侧掌侧(VU)入路。采用由内向外的方法建立桡侧掌侧中腕(VR-MC)和尺侧掌侧中腕(VU-MC)入路。然后在3.5倍放大镜下解剖手臂。由两名接受过专科培训的手外科医生使用数字卡尺测量入路与周围解剖结构之间的距离。
正中神经与VR、VU、VR-MC和VU-MC套管针的平均距离分别为1.6、7.2、1.8和5.6毫米。在一个标本中,VR入路穿刺了正中神经筋膜。在任何标本中,桡动脉、尺动脉和尺神经均未被穿刺。与历史对照相比,对于VR-MC入路,除桡动脉外,纳米关节镜离所有关键结构更远,且未穿刺任何神经血管结构。对于VU-MC入路,纳米关节镜离尺动脉和正中神经更远,且未穿刺任何神经血管结构。
在建立掌侧入路时,在由内向外将套管穿过掌侧关节囊后,我们建议做一个掌侧切口并解剖局部解剖结构以防止损伤。与历史对照相比,纳米关节镜通常离神经血管结构更远。