Suppr超能文献

CUSA 清晰软组织切除研究:CUSA 清晰超声手术吸引系统用于肝切除术中软组织切除的临床性能研究。

The CUSA Clarity Soft Tissue Removal Study: Clinical Performance Investigation of the CUSA Clarity Ultrasonic Surgical Aspirator System for Soft Tissue Removal During Liver Surgery.

机构信息

Department for the Treatment and Study of Abdominal Diseases and Abdominal Transplantation, Istituto di Ricovero e Cura a Carattere Scientifico-Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione (IRCCS-ISMETT), University of Pittsburgh Medical Center (UPMC), Palermo, Italy.

Department of Surgery and Medical and Surgical Specialties, University of Catania, Catania, Italy.

出版信息

J Laparoendosc Adv Surg Tech A. 2024 Feb;34(2):99-105. doi: 10.1089/lap.2023.0467. Epub 2024 Jan 31.

Abstract

Intraoperative blood loss has an unfavorable impact on the outcome of patients undergoing liver surgery. Today, the use of devices capable of minimizing this risk with high technical performance becomes mandatory. Into this scenario fits the CUSA Clarity Ultrasonic Surgical Aspirator System. This prospective survey involving five liver surgery centers had the objective of investigating whether this innovative ultrasonic surgical aspirator is safe and effective in the transection of the liver parenchyma. This clinical study was a prospective, multicenter, single-arm Post-Market Clinical Follow-up study investigating 100 subjects who underwent liver surgery using the CUSA Clarity Ultrasonic Surgical Aspirator System at five centers during a period of 1 year and 8 months. After collecting all the patient's clinical information and instrument usage details, surgeons completed a brief survey giving their opinions on the performance of CUSA. Therefore, safety and efficacy outcomes were evaluated. Surgeons had a 95% success rate in complete removal of the mass with an average overall operative time of 4 hours and 34 minutes. Overall, there were no complications or device deficiencies. The CUSA Clarity Ultrasonic Surgical Aspirator System performs well during liver surgery with a low complication rate. ClinicalTrials.gov Identifier: NCT04298268.

摘要

术中失血对接受肝脏手术的患者的预后有不利影响。如今,使用能够以高技术性能最大限度降低这种风险的设备已成为必要。CUSA Clarity 超声外科吸引系统就是这种情况下的理想选择。这项涉及五个肝脏手术中心的前瞻性调查旨在研究这种创新的超声外科吸引器在肝脏实质切割中是否安全有效。这项临床研究是一项前瞻性、多中心、单臂上市后临床随访研究,调查了 100 名患者,他们在 1 年零 8 个月期间在五个中心使用 CUSA Clarity 超声外科吸引系统进行了肝脏手术。在收集了所有患者的临床信息和仪器使用细节后,外科医生完成了一项简短的调查,就 CUSA 的性能发表了意见。因此,评估了安全性和疗效结果。外科医生以 95%的成功率成功切除了肿块,平均总手术时间为 4 小时 34 分钟。总体而言,没有发生并发症或设备缺陷。CUSA Clarity 超声外科吸引系统在肝脏手术中表现良好,并发症发生率低。ClinicalTrials.gov 标识符:NCT04298268。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验