Moore E N, Spear J F, Wetstein L, Michelson E L
P R Health Sci J. 1985 Jun;4(2):91-4.
Programmed electrical stimulation has provided a unique new opportunity to evaluate both mechanisms and treatment regimens aimed at preventing ventricular tachyarrhythmias. The variable results that have been reported from different laboratories, undoubtedly are due in part to the differences in programmed electrical stimulation protocols. Although it is unlikely that all laboratories will adapt the same programmed electrical stimulation protocol, it nevertheless is very important that the number of sites of stimulation, stimulus strength, stimulus duration, stimulus polarity, drive train length, and patient population all be listed in order for some comparison between laboratories to be made.
程控电刺激为评估旨在预防室性快速性心律失常的机制和治疗方案提供了一个独特的新机会。不同实验室报告的结果各异,这无疑部分归因于程控电刺激方案的差异。尽管不太可能所有实验室都采用相同的程控电刺激方案,但列出刺激部位数量、刺激强度、刺激持续时间、刺激极性、驱动链长度和患者群体等信息对于不同实验室之间进行某种比较而言非常重要。