Turetta F, de Stefani R, Milanesi A, Cannizzaro A, Padoan A M, de Giorgio P
J Fr Ophtalmol. 1985;8(12):785-8.
The authors have demonstrated a significant decrease of the plasmatic ionized calcium level in 84 patients during retinal fluorangiography likely due to a chemical bond between calcium and fluorescein. The side effects noticed during the procedure were similar to that quoted in the literature; their frequency, however, was not correlated with the decrease of the plasmatic ionized calcium level, even though the magnitude of the decrease was twice as great in the patients who experienced some trouble as in those who did not. This lack of correlation may be related to the too small patients sample. A greater frequency of side effects has been noticed in patients treated by calcium inhibitors.
作者们已证实在84例患者进行视网膜荧光血管造影期间血浆离子钙水平显著下降,这可能是由于钙与荧光素之间形成了化学键。该操作过程中观察到的副作用与文献中所引用的类似;然而,其发生频率与血浆离子钙水平的下降并无关联,尽管在出现某些问题的患者中钙水平下降幅度是未出现问题患者的两倍。这种缺乏相关性可能与患者样本过小有关。在接受钙抑制剂治疗的患者中观察到副作用的发生频率更高。